[Mon Jan 30 00:16:18 2012] Detection parameters: Position = (360.0, 676.2) = 3 24 38.53 -62 35 14.0 Extent = 0.5" x 0.5", rotation angle = 44 degrees Source counts = 3.7 +/- 2.0 Background counts = 0.3 Rate = 0.0002 +/- 8e-05 [Mon Jan 30 00:16:18 2012] Off-axis axis estimate = 3.86' [Mon Jan 30 01:05:24 2012] Using EEF radius (= 0.79 ")to estimate initial spatial extent for simple fitting [Mon Jan 30 01:05:24 2012] Initial guess for spatial extent in simple fitting = 0.79" [Mon Jan 30 01:05:24 2012] Spatial fitting skipped for pass 0: source has 3.7 net counts, is at off-axis angle 3.9' [Mon Jan 30 01:38:09 2012] Vigneting correction estimate = 1.000000 [Mon Jan 30 01:38:09 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Mon Jan 30 01:38:09 2012] Assessing source extent using major [Mon Jan 30 01:38:09 2012] Source does appear to be extended [Mon Jan 30 01:38:09 2012] Computing asymmetry using major and minor axis, asym = 1.02 [Mon Jan 30 02:20:45 2012] Using EEF radius (= 0.79 ")to estimate initial spatial extent for simple fitting [Mon Jan 30 02:20:45 2012] Initial guess for spatial extent in simple fitting = 0.79" [Mon Jan 30 02:20:45 2012] Spatial fitting skipped for pass 1: source has 3.7 net counts, is at off-axis angle 3.9' [Mon Jan 30 02:48:04 2012] Vigneting correction estimate = 1.000000 [Mon Jan 30 02:48:04 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Mon Jan 30 02:48:04 2012] Assessing source extent using major [Mon Jan 30 02:48:04 2012] Source does appear to be extended [Mon Jan 30 02:48:04 2012] Computing asymmetry using major and minor axis, asym = 1.02 [Mon Jan 30 02:48:04 2012] Deleting source due to low Poisson probability 0.9