[Mon Oct 10 02:47:35 2011] Detection parameters: Position = (358.5, 725.5) = 14 15 19.56 36 14 7.7 Extent = 0.9" x 0.6", rotation angle = 55 degrees Source counts = 14.7 +/- 4.2 Background counts = 3.3 Rate = 0.0003 +/- 8e-05 [Mon Oct 10 02:47:35 2011] Off-axis axis estimate = 3.59' [Mon Oct 10 04:00:57 2011] Using EEF radius (= 0.71 ")to estimate initial spatial extent for simple fitting [Mon Oct 10 04:00:57 2011] Initial guess for spatial extent in simple fitting = 0.71" [Mon Oct 10 04:00:57 2011] source mask rpix=1.5, npix_max = 15, mask sum = 9, frac = 0.591 [Mon Oct 10 04:00:57 2011] Giving source the simple spatial ID 25 for pass 0, mean size = 0.71" [Mon Oct 10 04:29:58 2011] fullrun_ccd7_acisf13119_pi14-548_cl_pass0_src25.ximg exists [Mon Oct 10 04:29:58 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_ccd7_acisf13119_pi14-548_cl_pass0_src25.csv [Mon Oct 10 04:29:58 2011] fullrun_ccd7_acisf13119_pi14-548_cl_pass0_src25_1.ximg exists [Mon Oct 10 04:29:58 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_ccd7_acisf13119_pi14-548_cl_pass0_src25.csv [Mon Oct 10 04:29:58 2011] It looks like the fit did not converge You should probably delete fullrun_ccd7_acisf13119_pi14-548_cl_pass0_src25_1.ximg Either tweak this fit manually starting from fullrun_ccd7_acisf13119_pi14-548_cl_pass0_src25.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Mon Oct 10 04:29:58 2011] fullrun_ccd7_acisf13119_pi14-548_cl_pass0_tfrozen_src25.ximg exists [Mon Oct 10 04:29:58 2011] fullrun_ccd7_acisf13119_pi14-548_cl_pass0_tfrozen_src25_1.ximg exists [Mon Oct 10 04:29:58 2011] Fit fullrun_ccd7_acisf13119_pi14-548_cl_pass0_tfrozen_src25 appears to have run properly [Mon Oct 10 04:30:09 2011] Spatial fit model total counts = 22.238900, observed total counts = 22.000000 [Mon Oct 10 04:30:09 2011] Offset between fit and detection position for source 25 = 1.065672 pixels [Mon Oct 10 04:30:09 2011] 21.413050 total counts/ 4.306450 bgd. counts: snr = 8.243355 Spatial fit parameters: Offset between fit and detection position for source 25 = 1.065672 pixels Position = (359.3, 726.3) = 14 15 19.55 36 14 7.9 Extent = 1.0 (0.7-1.5)", rotation angle = 0 Source counts = 17.1 +/- 4.6 Background counts = 4.3 Rate = 0.0003 +/- 9e-05 [Mon Oct 10 04:30:09 2011] Vigneting correction estimate = 1.000000 [Mon Oct 10 04:30:09 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Mon Oct 10 04:30:09 2011] Assessing source extent using major axis lower bound [Mon Oct 10 04:30:09 2011] Source does appear to be extended [Mon Oct 10 04:30:09 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Mon Oct 10 05:25:52 2011] Using previous fit value to estimate initial spatial extent for simple fitting [Mon Oct 10 05:25:52 2011] Initial guess for spatial extent in simple fitting = 0.96" [Mon Oct 10 05:25:52 2011] source mask rpix=2.0, npix_max = 24, mask sum = 25, frac = 1.034 [Mon Oct 10 05:25:52 2011] Giving source the simple spatial ID 25 for pass 1, mean size = 0.96" [Mon Oct 10 05:56:11 2011] fullrun_ccd7_acisf13119_pi14-548_cl_pass1_src25.ximg exists [Mon Oct 10 05:56:11 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_ccd7_acisf13119_pi14-548_cl_pass1_src25.csv [Mon Oct 10 05:56:11 2011] fullrun_ccd7_acisf13119_pi14-548_cl_pass1_src25_1.ximg exists [Mon Oct 10 05:56:11 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_ccd7_acisf13119_pi14-548_cl_pass1_src25.csv [Mon Oct 10 05:56:11 2011] It looks like the fit did not converge You should probably delete fullrun_ccd7_acisf13119_pi14-548_cl_pass1_src25_1.ximg Either tweak this fit manually starting from fullrun_ccd7_acisf13119_pi14-548_cl_pass1_src25.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Mon Oct 10 05:56:11 2011] fullrun_ccd7_acisf13119_pi14-548_cl_pass1_tfrozen_src25.ximg exists [Mon Oct 10 05:56:12 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_ccd7_acisf13119_pi14-548_cl_pass1_tfrozen_src25.csv [Mon Oct 10 05:56:12 2011] fullrun_ccd7_acisf13119_pi14-548_cl_pass1_tfrozen_src25_1.ximg exists [Mon Oct 10 05:56:12 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_ccd7_acisf13119_pi14-548_cl_pass1_tfrozen_src25.csv [Mon Oct 10 05:56:12 2011] It looks like the fit did not converge You should probably delete fullrun_ccd7_acisf13119_pi14-548_cl_pass1_tfrozen_src25_1.ximg Either tweak this fit manually starting from fullrun_ccd7_acisf13119_pi14-548_cl_pass1_tfrozen_src25.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Mon Oct 10 05:56:21 2011] Spatial fit model total counts = 18.275600, observed total counts = 21.000000 [Mon Oct 10 05:56:21 2011] Offset between fit and detection position for source 25 = 0.670657 pixels [Mon Oct 10 05:56:21 2011] 18.698807 total counts/ 0.467207 bgd. counts: snr = 26.672892 Spatial fit parameters: Offset between fit and detection position for source 25 = 0.670657 pixels Position = (359.0, 725.6) = 14 15 19.56 36 14 7.6 Extent = 1.2" x 0.8", rotation angle = 127 Source counts = 18.2 +/- 4.3 Background counts = 0.5 Rate = 0.0003 +/- 8e-05 [Mon Oct 10 05:56:21 2011] Vigneting correction estimate = 1.000000 [Mon Oct 10 05:56:21 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Mon Oct 10 05:56:21 2011] Assessing source extent using major [Mon Oct 10 05:56:21 2011] Source does appear to be extended [Mon Oct 10 05:56:21 2011] Computing asymmetry using major and minor axis, asym = 1.47 [Mon Oct 10 06:12:21 2011] Writing source region out to fullrun_ccd7_acisf13119_pi14-548_pass1_cl_src25_src.reg [Mon Oct 10 06:12:21 2011] Extracting stamp from image fullrun_ccd7_acisf13119_pi14-548_cl_sm2.00.img.gz, (303, 670) - (415, 781) [Mon Oct 10 06:12:21 2011] Writing fullrun_ccd7_acisf13119_pi14-548_pass1_cl_src25.gif [Mon Oct 10 06:19:39 2011] Size of ../../acisf13119/products/events/fullrun_ccd7_acisf13119_pi14-548_pass1_cl_src25_src.evt.gz[events] = 19 counts [Mon Oct 10 06:19:39 2011] Mean chipx,y = (527.74, 216.84) [Mon Oct 10 06:19:39 2011] Mean tdetx,y = (4444.74, 1918.84) [Mon Oct 10 06:19:39 2011] chipx,y range = (503.00-544.00, 200.00-234.00) [Mon Oct 10 06:19:39 2011] Size of ../../acisf13119/products/events/fullrun_ccd7_acisf13119_pi14-548_pass1_cl_src25_bgd.evt.gz[events] = 138 counts [Mon Oct 10 06:19:40 2011] Not generating rmf since there are only 18 counts [Mon Oct 10 06:19:40 2011] arf not found, will run specextract [Mon Oct 10 06:19:48 2011] ../../acisf13119/products/spectra/fullrun_ccd7_acisf13119_pi14-548_pass1_cl_src25.warf not found [Mon Oct 10 06:19:48 2011] ../../acisf13119/products/spectra/fullrun_ccd7_acisf13119_pi14-548_pass1_cl_src25.wrmf not found [Mon Oct 10 06:19:48 2011] Removal of ../../acisf13119/products/spectra/fullrun_ccd7_acisf13119_pi14-548_pass1_cl_src25.soff failed [Mon Oct 10 06:22:45 2011] Spectrum 25 has only 18 counts, deleting rmf [Mon Oct 10 06:22:45 2011] 209.105 [Mon Oct 10 06:22:48 2011] Updating aperture counts using extracted products [Mon Oct 10 06:22:48 2011] Error reading totcts from fullrun_ccd7_acisf13119_pi14-548_pass1_cl_src25_src.pi.gz [Mon Oct 10 06:22:48 2011] Calculating source flux in energy range 0.30-8.00 [Mon Oct 10 06:22:48 2011] Using photon index=1.80, rate=0.000336, arf fullrun_ccd7_acisf13119_pi14-548_pass1_cl_src25.arf [Mon Oct 10 06:22:48 2011] Assuming count rate is from the 0.20-8.00 bandpass [Mon Oct 10 06:22:48 2011] Updating source flux to 2.8e-15 [Mon Oct 10 06:23:02 2011] Source 25 has fewer than 100.000000 counts, skipping spectral fitting