skip = machinename xassist.localdomain process id = 9276: smart_fit pl logroot=fullrun_ccd7_acisf12619_pi14-548_pass1_cl_src2_pl flux_elow=0.300000 flux_ehi=8.000000 2 parameters in pl dchi = 4.605 F(2.0-10.0 keV) = 4.98e-14 Count rates: 0.001952 Entry point parameter values: Nh = 7.97e-10 () Gamma = 0.61 () Starting error search... Getting error on parameter #2 = Nh smart_error exited normally Hard limit reached before req. deltachisq for lower bound Nh = 7.97e-10 (0 - 0.729) Getting error on parameter #3 = Gamma smart_error exited normally Gamma = 0.61 (-0.0795 - 1.3) Saving fit as fullrun_ccd7_acisf12619_pi14-548_pass1_cl_src2_pl_new.xcm in order to save the revised "delta" values (to improve future error search efficiency) Final chisq(dof) = 9.248(6) F(0.5-2.0 keV) = 5.082e-15 F(2.0-10.0 keV) = 4.98e-14 F(0.3-8.0) = 4.045e-14 Count rates: 0.001952