[Tue Jun 19 10:32:09 2012] Detection parameters: Position = (1092.2, 671.8) = 16 35 23.91 -47 20 23.6 Extent = 0.5" x 0.5", rotation angle = 5 degrees Source counts = 2.5 +/- 1.7 Background counts = 0.5 Rate = 0.0001 +/- 9e-05 [Tue Jun 19 10:32:09 2012] Off-axis axis estimate = 7.31' [Tue Jun 19 10:52:48 2012] Using EEF radius (= 2.37 ")to estimate initial spatial extent for simple fitting [Tue Jun 19 10:52:48 2012] Initial guess for spatial extent in simple fitting = 2.37" [Tue Jun 19 10:52:48 2012] Spatial fitting skipped for pass 0: source has 2.5 net counts, is at off-axis angle 7.3' [Tue Jun 19 11:00:37 2012] Vigneting correction estimate = 1.000000 [Tue Jun 19 11:00:37 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Jun 19 11:00:37 2012] Assessing source extent using major [Tue Jun 19 11:00:37 2012] Source does appear to be extended [Tue Jun 19 11:00:37 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Tue Jun 19 11:21:36 2012] Using EEF radius (= 2.37 ")to estimate initial spatial extent for simple fitting [Tue Jun 19 11:21:36 2012] Initial guess for spatial extent in simple fitting = 2.37" [Tue Jun 19 11:21:36 2012] Spatial fitting skipped for pass 1: source has 2.5 net counts, is at off-axis angle 7.3' [Tue Jun 19 11:30:44 2012] Vigneting correction estimate = 1.000000 [Tue Jun 19 11:30:44 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Jun 19 11:30:44 2012] Assessing source extent using major [Tue Jun 19 11:30:44 2012] Source does appear to be extended [Tue Jun 19 11:30:44 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Tue Jun 19 11:30:44 2012] Deleting source due to low Poisson probability 0.9