[Tue Jun 19 10:31:02 2012] Detection parameters: Position = (155.8, 696.2) = 16 35 45.19 -47 27 53.4 Extent = 0.5" x 0.5", rotation angle = 90 degrees Source counts = 2.9 +/- 1.7 Background counts = 0.1 Rate = 0.0002 +/- 9e-05 [Tue Jun 19 10:31:02 2012] Off-axis axis estimate = 2.94' [Tue Jun 19 10:41:54 2012] Using EEF radius (= 0.57 ")to estimate initial spatial extent for simple fitting [Tue Jun 19 10:41:54 2012] Initial guess for spatial extent in simple fitting = 0.57" [Tue Jun 19 10:41:54 2012] Spatial fitting skipped for pass 0: source has 2.9 net counts, is at off-axis angle 2.9' [Tue Jun 19 11:00:35 2012] Vigneting correction estimate = 1.000000 [Tue Jun 19 11:00:35 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Jun 19 11:00:35 2012] Assessing source extent using major [Tue Jun 19 11:00:35 2012] Source does appear to be extended [Tue Jun 19 11:00:35 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Tue Jun 19 11:08:49 2012] Using EEF radius (= 0.57 ")to estimate initial spatial extent for simple fitting [Tue Jun 19 11:08:49 2012] Initial guess for spatial extent in simple fitting = 0.57" [Tue Jun 19 11:08:49 2012] Spatial fitting skipped for pass 1: source has 2.9 net counts, is at off-axis angle 2.9' [Tue Jun 19 11:30:43 2012] Vigneting correction estimate = 1.000000 [Tue Jun 19 11:30:43 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Jun 19 11:30:43 2012] Assessing source extent using major [Tue Jun 19 11:30:43 2012] Source does appear to be extended [Tue Jun 19 11:30:43 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Tue Jun 19 11:30:43 2012] Deleting source due to low Poisson probability 0.8