[Tue Jan 17 15:35:37 2012] Detection parameters: Position = (224.0, 557.8) = 3 32 43.88 -27 54 54.2 Extent = 1.5" x 1.0", rotation angle = 51 degrees Source counts = 8.7 +/- 3.3 Background counts = 2.3 Rate = 0.0003 +/- 0.0001 [Tue Jan 17 15:35:38 2012] Off-axis axis estimate = 7.76' [Tue Jan 17 16:15:08 2012] Using EEF radius (= 2.67 ")to estimate initial spatial extent for simple fitting [Tue Jan 17 16:15:08 2012] Setting initial spatial extent for simple fitting to maximum allowed for this pass [Tue Jan 17 16:15:08 2012] Initial guess for spatial extent in simple fitting = 2.67" [Tue Jan 17 16:15:08 2012] Spatial fitting skipped for pass 0: source has 8.7 net counts, is at off-axis angle 7.8' [Tue Jan 17 16:30:05 2012] Vigneting correction estimate = 1.000000 [Tue Jan 17 16:30:05 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Jan 17 16:30:05 2012] Assessing source extent using major [Tue Jan 17 16:30:05 2012] Source does appear to be extended [Tue Jan 17 16:30:05 2012] Computing asymmetry using major and minor axis, asym = 1.58 [Tue Jan 17 16:30:05 2012] Source is asymmetric [Tue Jan 17 17:09:43 2012] Using EEF radius (= 2.67 ")to estimate initial spatial extent for simple fitting [Tue Jan 17 17:09:43 2012] Setting initial spatial extent for simple fitting to maximum allowed for this pass [Tue Jan 17 17:09:43 2012] Initial guess for spatial extent in simple fitting = 2.67" [Tue Jan 17 17:09:43 2012] Spatial fitting skipped for pass 1: source has 8.7 net counts, is at off-axis angle 7.8' [Tue Jan 17 17:24:00 2012] Vigneting correction estimate = 1.000000 [Tue Jan 17 17:24:00 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Jan 17 17:24:00 2012] Assessing source extent using major [Tue Jan 17 17:24:00 2012] Source does appear to be extended [Tue Jan 17 17:24:00 2012] Computing asymmetry using major and minor axis, asym = 1.58 [Tue Jan 17 17:24:00 2012] Source is asymmetric [Tue Jan 17 17:50:10 2012] Writing source region out to fullrun_ccd3_acisf12230_pi14-548_pass1_cl_src6_src.reg [Tue Jan 17 17:50:10 2012] Extracting stamp from image fullrun_ccd3_acisf12230_pi14-548_cl_sm2.00.img.gz, (154, 488) - (294, 628) [Tue Jan 17 17:50:10 2012] Writing fullrun_ccd3_acisf12230_pi14-548_pass1_cl_src6.gif [Tue Jan 17 17:54:25 2012] Size of ../../acisf12230/products/events/fullrun_ccd3_acisf12230_pi14-548_pass1_cl_src6_src.evt.gz[events] = 13 counts [Tue Jan 17 17:54:25 2012] Mean chipx,y = (813.31, 87.46) [Tue Jan 17 17:54:25 2012] Mean tdetx,y = (5044.54, 3874.31) [Tue Jan 17 17:54:25 2012] chipx,y range = (794.00-834.00, 71.00-109.00) [Tue Jan 17 17:54:25 2012] Size of ../../acisf12230/products/events/fullrun_ccd3_acisf12230_pi14-548_pass1_cl_src6_bgd.evt.gz[events] = 58 counts [Tue Jan 17 17:54:26 2012] Not generating rmf since there are only 8 counts [Tue Jan 17 17:54:26 2012] arf not found, will run specextract [Tue Jan 17 17:54:38 2012] ../../acisf12230/products/spectra/fullrun_ccd3_acisf12230_pi14-548_pass1_cl_src6.warf not found [Tue Jan 17 17:54:38 2012] ../../acisf12230/products/spectra/fullrun_ccd3_acisf12230_pi14-548_pass1_cl_src6.wrmf not found [Tue Jan 17 17:54:38 2012] Removal of ../../acisf12230/products/spectra/fullrun_ccd3_acisf12230_pi14-548_pass1_cl_src6.soff failed [Tue Jan 17 18:00:44 2012] Spectrum 6 has only 9 counts, deleting rmf [Tue Jan 17 18:00:44 2012] 173.919 [Tue Jan 17 18:01:29 2012] Updating aperture counts using extracted products [Tue Jan 17 18:01:29 2012] Error reading totcts from fullrun_ccd3_acisf12230_pi14-548_pass1_cl_src6_src.pi.gz [Tue Jan 17 18:01:29 2012] Calculating source flux in energy range 0.30-8.00 [Tue Jan 17 18:01:29 2012] Using photon index=1.80, rate=0.000258, arf fullrun_ccd3_acisf12230_pi14-548_pass1_cl_src6.arf [Tue Jan 17 18:01:29 2012] Assuming count rate is from the 0.20-8.00 bandpass [Tue Jan 17 18:01:29 2012] Updating source flux to 3.6e-15 [Tue Jan 17 18:01:43 2012] Simple spatial fitting not done (or not done successfully), skipping spectral fitting [Tue Jan 17 18:01:44 2012] acisf12230/analysis//spectral/fullrun_ccd3_acisf12230_pi14-548_pass1_cl_src6_pl.csv not found, spectral fit skipped or did not complete