[Sat Sep 24 08:32:17 2011] Detection parameters: Position = (450.3, 762.2) = 0 52 0.02 -73 21 14.2 Extent = 0.6" x 0.5", rotation angle = 75 degrees Source counts = 7.8 +/- 3.0 Background counts = 1.2 Rate = 0.0003 +/- 0.0001 [Sat Sep 24 08:32:19 2011] Off-axis axis estimate = 4.09' [Sat Sep 24 08:33:06 2011] Using EEF radius (= 0.86 ")to estimate initial spatial extent for simple fitting [Sat Sep 24 08:33:06 2011] Initial guess for spatial extent in simple fitting = 0.86" [Sat Sep 24 08:33:06 2011] Spatial fitting skipped for pass 0: source has 7.8 net counts, is at off-axis angle 4.1' [Sat Sep 24 08:33:20 2011] Vigneting correction estimate = 1.000000 [Sat Sep 24 08:33:20 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Sat Sep 24 08:33:20 2011] Assessing source extent using major [Sat Sep 24 08:33:20 2011] Source does appear to be extended [Sat Sep 24 08:33:20 2011] Computing asymmetry using major and minor axis, asym = 1.13 [Sat Sep 24 08:33:20 2011] Deleting source due to low Poisson probability 0.9