[Mon May 13 12:12:45 2013] Detection parameters: Position = (405.2, 947.5) = 11 54 13.38 23 24 27.9 Extent = 0.5" x 0.5", rotation angle = 62 degrees Source counts = 3.0 +/- 1.7 Background counts = 0.0 Rate = 0.0006 +/- 0.0004 [Mon May 13 12:12:45 2013] Off-axis axis estimate = 2.55' [Mon May 13 12:21:43 2013] Using EEF radius (= 0.50 ")to estimate initial spatial extent for simple fitting [Mon May 13 12:21:43 2013] Initial guess for spatial extent in simple fitting = 0.50" [Mon May 13 12:21:43 2013] Spatial fitting skipped for pass 0: source has 3.0 net counts, is at off-axis angle 2.6' [Mon May 13 12:24:30 2013] Vigneting correction estimate = 1.000000 [Mon May 13 12:24:30 2013] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Mon May 13 12:24:30 2013] Assessing source extent using major [Mon May 13 12:24:30 2013] Source does appear to be extended [Mon May 13 12:24:30 2013] Computing asymmetry using major and minor axis, asym = 1.00 [Mon May 13 12:31:13 2013] Using EEF radius (= 0.50 ")to estimate initial spatial extent for simple fitting [Mon May 13 12:31:13 2013] Initial guess for spatial extent in simple fitting = 0.50" [Mon May 13 12:31:13 2013] Spatial fitting skipped for pass 1: source has 3.0 net counts, is at off-axis angle 2.6' [Mon May 13 12:33:16 2013] Vigneting correction estimate = 1.000000 [Mon May 13 12:33:16 2013] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Mon May 13 12:33:16 2013] Assessing source extent using major [Mon May 13 12:33:16 2013] Source does appear to be extended [Mon May 13 12:33:16 2013] Computing asymmetry using major and minor axis, asym = 1.00 [Mon May 13 12:33:16 2013] Deleting source due to low Poisson probability 0.9