[Wed Oct 26 07:31:55 2011] Detection parameters: Position = (498.8, 469.5) = 11 42 57.36 50 54 44.8 Extent = 0.5" x 0.5", rotation angle = 35 degrees Source counts = 3.3 +/- 2.0 Background counts = 0.7 Rate = 0.0002 +/- 0.0001 [Wed Oct 26 07:31:55 2011] Off-axis axis estimate = 4.27' [Wed Oct 26 07:32:40 2011] Using EEF radius (= 0.91 ")to estimate initial spatial extent for simple fitting [Wed Oct 26 07:32:40 2011] Initial guess for spatial extent in simple fitting = 0.91" [Wed Oct 26 07:32:40 2011] Spatial fitting skipped for pass 0: source has 3.3 net counts, is at off-axis angle 4.3' [Wed Oct 26 07:32:47 2011] Vigneting correction estimate = 1.000000 [Wed Oct 26 07:32:47 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Wed Oct 26 07:32:47 2011] Assessing source extent using major [Wed Oct 26 07:32:47 2011] Source does appear to be extended [Wed Oct 26 07:32:47 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Wed Oct 26 07:32:47 2011] Deleting source due to low Poisson probability 0.9