[Tue Nov 1 06:15:45 2011] Detection parameters: Position = (1117.6, 632.4) = 23 23 4.05 58 48 33.4 Extent = 0.7" x 0.6", rotation angle = 14 degrees Source counts = 263.3 +/- 23.1 Background counts = 271.7 Rate = 0.01 +/- 0.001 [Tue Nov 1 06:17:09 2011] Off-axis axis estimate = 2.70' [Tue Nov 1 06:28:25 2011] Using EEF radius (= 0.52 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:28:25 2011] Initial guess for spatial extent in simple fitting = 0.52" [Tue Nov 1 06:28:25 2011] source mask rpix=1.1, npix_max = 9, mask sum = 9, frac = 0.919 [Tue Nov 1 06:28:25 2011] Giving source the simple spatial ID 840 for pass 0, mean size = 0.52" [Tue Nov 1 06:29:26 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:29:26 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:29:26 2011] Assessing source extent using major [Tue Nov 1 06:29:26 2011] Source does appear to be extended [Tue Nov 1 06:29:26 2011] Computing asymmetry using major and minor axis, asym = 1.22 [Tue Nov 1 06:30:41 2011] Using EEF radius (= 0.52 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:30:41 2011] Initial guess for spatial extent in simple fitting = 0.52" [Tue Nov 1 06:30:41 2011] source mask rpix=1.1, npix_max = 9, mask sum = 9, frac = 0.919 [Tue Nov 1 06:30:41 2011] Giving source the simple spatial ID 787 for pass 1, mean size = 0.52" [Tue Nov 1 06:31:49 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:31:49 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:31:49 2011] Assessing source extent using major [Tue Nov 1 06:31:49 2011] Source does appear to be extended [Tue Nov 1 06:31:49 2011] Computing asymmetry using major and minor axis, asym = 1.22 [Tue Nov 1 06:33:56 2011] Not overwriting source region fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src847_src.reg [Tue Nov 1 06:33:56 2011] Extracting stamp from image fullrun_ccd7_acisf12020_pi14-548_cl_sm2.00.img.gz, (1087, 602) - (1148, 663) [Tue Nov 1 06:33:56 2011] Writing fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src847.gif [Tue Nov 1 07:23:01 2011] ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src847_src.evt and ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src847_bgd.evt exist, delete to re-create [Tue Nov 1 07:23:01 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src847_src.evt.gz[events] = 400 counts [Tue Nov 1 07:23:01 2011] Mean chipx,y = (235.09, 830.79) [Tue Nov 1 07:23:01 2011] Mean tdetx,y = (4152.09, 2532.79) [Tue Nov 1 07:23:01 2011] chipx,y range = (215.00-255.00, 810.00-851.00) [Tue Nov 1 07:23:01 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src847_bgd.evt.gz[events] = 2195 counts [Tue Nov 1 07:23:01 2011] ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src847_src.img and ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src847_bgd.img exist, delete to re-create [Tue Nov 1 07:23:01 2011] ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src847_src.pi and ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src847_bgd.pi exist, delete to re-create [Tue Nov 1 07:23:01 2011] Not generating rmf since RequireSpatial is true but spatial fitting not done [Tue Nov 1 07:23:04 2011] ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src847_src.lc and ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src847_bgd.lc exist, delete to re-create [Tue Nov 1 07:32:21 2011] Keeping rmf generated by specextract [Tue Nov 1 07:32:21 2011] 222.316 [Tue Nov 1 07:33:26 2011] Updating aperture counts using extracted products [Tue Nov 1 07:33:26 2011] Error reading totcts from fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src847_src.pi.gz [Tue Nov 1 07:34:18 2011] Calculating source flux in energy range 0.30-8.00 [Tue Nov 1 07:34:18 2011] Using photon index=1.80, rate=0.0118, arf fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src847.arf [Tue Nov 1 07:34:18 2011] Assuming count rate is from the 0.20-8.00 bandpass [Tue Nov 1 07:34:18 2011] Updating source flux to 1.1e-13 [Tue Nov 1 07:34:39 2011] Simple spatial fitting not done (or not done successfully), skipping spectral fitting