[Tue Nov 1 06:14:49 2011] Detection parameters: Position = (897.2, 846.6) = 23 23 18.01 58 50 18.8 Extent = 0.7" x 0.7", rotation angle = 146 degrees Source counts = 1431.4 +/- 69.3 Background counts = 3367.6 Rate = 0.06 +/- 0.003 [Tue Nov 1 06:17:09 2011] Off-axis axis estimate = 3.42' [Tue Nov 1 06:28:25 2011] Using EEF radius (= 0.67 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:28:25 2011] Initial guess for spatial extent in simple fitting = 0.67" [Tue Nov 1 06:28:25 2011] source mask rpix=1.4, npix_max = 13, mask sum = 12, frac = 0.862 [Tue Nov 1 06:28:25 2011] Giving source the simple spatial ID 570 for pass 0, mean size = 0.67" [Tue Nov 1 06:29:25 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:29:25 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:29:25 2011] Assessing source extent using major [Tue Nov 1 06:29:25 2011] Source does appear to be extended [Tue Nov 1 06:29:25 2011] Computing asymmetry using major and minor axis, asym = 1.03 [Tue Nov 1 06:30:41 2011] Using EEF radius (= 0.67 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:30:41 2011] Initial guess for spatial extent in simple fitting = 0.67" [Tue Nov 1 06:30:41 2011] source mask rpix=1.4, npix_max = 13, mask sum = 12, frac = 0.862 [Tue Nov 1 06:30:41 2011] Giving source the simple spatial ID 570 for pass 1, mean size = 0.67" [Tue Nov 1 06:31:49 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:31:49 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:31:49 2011] Assessing source extent using major [Tue Nov 1 06:31:49 2011] Source does appear to be extended [Tue Nov 1 06:31:49 2011] Computing asymmetry using major and minor axis, asym = 1.03 [Tue Nov 1 06:33:44 2011] Not overwriting source region fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src575_src.reg [Tue Nov 1 06:33:44 2011] Extracting stamp from image fullrun_ccd7_acisf12020_pi14-548_cl_sm2.00.img.gz, (864, 813) - (931, 880) [Tue Nov 1 06:33:44 2011] Writing fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src575.gif [Tue Nov 1 07:09:16 2011] ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src575_src.evt and ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src575_bgd.evt exist, delete to re-create [Tue Nov 1 07:09:16 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src575_src.evt.gz[events] = 4746 counts [Tue Nov 1 07:09:16 2011] Mean chipx,y = (531.94, 747.56) [Tue Nov 1 07:09:16 2011] Mean tdetx,y = (4448.94, 2449.56) [Tue Nov 1 07:09:16 2011] chipx,y range = (508.00-554.00, 726.00-770.00) [Tue Nov 1 07:09:16 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src575_bgd.evt.gz[events] = 15532 counts [Tue Nov 1 07:09:16 2011] ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src575_src.img and ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src575_bgd.img exist, delete to re-create [Tue Nov 1 07:09:16 2011] ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src575_src.pi and ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src575_bgd.pi exist, delete to re-create [Tue Nov 1 07:09:16 2011] Not generating rmf since RequireSpatial is true but spatial fitting not done [Tue Nov 1 07:09:19 2011] ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src575_src.lc and ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src575_bgd.lc exist, delete to re-create [Tue Nov 1 07:32:03 2011] Keeping rmf generated by specextract [Tue Nov 1 07:32:03 2011] 213.692 [Tue Nov 1 07:33:13 2011] Updating aperture counts using extracted products [Tue Nov 1 07:33:13 2011] Error reading totcts from fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src575_src.pi.gz [Tue Nov 1 07:34:04 2011] Calculating source flux in energy range 0.30-8.00 [Tue Nov 1 07:34:04 2011] Using photon index=1.80, rate=0.064, arf fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src575.arf [Tue Nov 1 07:34:04 2011] Assuming count rate is from the 0.20-8.00 bandpass [Tue Nov 1 07:34:04 2011] Updating source flux to 6.3e-13 [Tue Nov 1 07:34:39 2011] Simple spatial fitting not done (or not done successfully), skipping spectral fitting