[Tue Nov 1 06:14:21 2011] Detection parameters: Position = (823.8, 712.9) = 23 23 22.66 58 49 13.0 Extent = 0.7" x 0.7", rotation angle = 66 degrees Source counts = 1792.0 +/- 66.0 Background counts = 2568.0 Rate = 0.08 +/- 0.003 [Tue Nov 1 06:17:09 2011] Off-axis axis estimate = 2.32' [Tue Nov 1 06:28:25 2011] Using EEF radius (= 0.47 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:28:25 2011] Initial guess for spatial extent in simple fitting = 0.47" [Tue Nov 1 06:28:25 2011] source mask rpix=0.9, npix_max = 8, mask sum = 9, frac = 1.071 [Tue Nov 1 06:28:25 2011] Giving source the simple spatial ID 445 for pass 0, mean size = 0.47" [Tue Nov 1 06:29:25 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:29:25 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:29:25 2011] Assessing source extent using major [Tue Nov 1 06:29:25 2011] Source does appear to be extended [Tue Nov 1 06:29:25 2011] Computing asymmetry using major and minor axis, asym = 1.09 [Tue Nov 1 06:30:41 2011] Using EEF radius (= 0.47 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:30:41 2011] Initial guess for spatial extent in simple fitting = 0.47" [Tue Nov 1 06:30:41 2011] source mask rpix=0.9, npix_max = 8, mask sum = 9, frac = 1.071 [Tue Nov 1 06:30:41 2011] Giving source the simple spatial ID 445 for pass 1, mean size = 0.47" [Tue Nov 1 06:31:49 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:31:49 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:31:49 2011] Assessing source extent using major [Tue Nov 1 06:31:49 2011] Source does appear to be extended [Tue Nov 1 06:31:49 2011] Computing asymmetry using major and minor axis, asym = 1.09 [Tue Nov 1 06:33:37 2011] Not overwriting source region fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src445_src.reg [Tue Nov 1 06:33:37 2011] Extracting stamp from image fullrun_ccd7_acisf12020_pi14-548_cl_sm2.00.img.gz, (790, 679) - (857, 746) [Tue Nov 1 06:33:37 2011] Writing fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src445.gif [Tue Nov 1 07:01:42 2011] ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src445_src.evt and ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src445_bgd.evt exist, delete to re-create [Tue Nov 1 07:01:42 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src445_src.evt.gz[events] = 2759 counts [Tue Nov 1 07:01:42 2011] Mean chipx,y = (452.67, 617.54) [Tue Nov 1 07:01:42 2011] Mean tdetx,y = (4369.67, 2319.54) [Tue Nov 1 07:01:42 2011] chipx,y range = (430.00-478.00, 595.00-639.00) [Tue Nov 1 07:01:42 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src445_bgd.evt.gz[events] = 10900 counts [Tue Nov 1 07:01:42 2011] ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src445_src.img and ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src445_bgd.img exist, delete to re-create [Tue Nov 1 07:01:42 2011] ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src445_src.pi and ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src445_bgd.pi exist, delete to re-create [Tue Nov 1 07:01:42 2011] Not generating rmf since RequireSpatial is true but spatial fitting not done [Tue Nov 1 07:01:46 2011] ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src445_src.lc and ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src445_bgd.lc exist, delete to re-create [Tue Nov 1 07:31:54 2011] Keeping rmf generated by specextract [Tue Nov 1 07:31:54 2011] 222.311 [Tue Nov 1 07:33:07 2011] Updating aperture counts using extracted products [Tue Nov 1 07:33:07 2011] Error reading totcts from fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src445_src.pi.gz [Tue Nov 1 07:33:57 2011] Calculating source flux in energy range 0.30-8.00 [Tue Nov 1 07:33:57 2011] Using photon index=1.80, rate=0.0801, arf fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src445.arf [Tue Nov 1 07:33:57 2011] Assuming count rate is from the 0.20-8.00 bandpass [Tue Nov 1 07:33:57 2011] Updating source flux to 7.6e-13 [Tue Nov 1 07:34:39 2011] Simple spatial fitting not done (or not done successfully), skipping spectral fitting