[Tue Nov 1 06:14:11 2011] Detection parameters: Position = (892.6, 669.1) = 23 23 18.30 58 48 51.5 Extent = 0.7" x 0.7", rotation angle = 105 degrees Source counts = 1731.7 +/- 63.8 Background counts = 2334.3 Rate = 0.08 +/- 0.003 [Tue Nov 1 06:17:09 2011] Off-axis axis estimate = 1.97' [Tue Nov 1 06:28:25 2011] Using EEF radius (= 0.43 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:28:25 2011] Initial guess for spatial extent in simple fitting = 0.43" [Tue Nov 1 06:28:25 2011] source mask rpix=0.9, npix_max = 7, mask sum = 6, frac = 0.803 [Tue Nov 1 06:28:25 2011] Giving source the simple spatial ID 403 for pass 0, mean size = 0.43" [Tue Nov 1 06:29:25 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:29:25 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:29:25 2011] Assessing source extent using major [Tue Nov 1 06:29:25 2011] Source does appear to be extended [Tue Nov 1 06:29:25 2011] Computing asymmetry using major and minor axis, asym = 1.09 [Tue Nov 1 06:30:41 2011] Using EEF radius (= 0.43 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:30:41 2011] Initial guess for spatial extent in simple fitting = 0.43" [Tue Nov 1 06:30:41 2011] source mask rpix=0.9, npix_max = 7, mask sum = 6, frac = 0.803 [Tue Nov 1 06:30:41 2011] Giving source the simple spatial ID 403 for pass 1, mean size = 0.43" [Tue Nov 1 06:31:49 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:31:49 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:31:49 2011] Assessing source extent using major [Tue Nov 1 06:31:49 2011] Source does appear to be extended [Tue Nov 1 06:31:49 2011] Computing asymmetry using major and minor axis, asym = 1.09 [Tue Nov 1 06:33:34 2011] Not overwriting source region fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src403_src.reg [Tue Nov 1 06:33:34 2011] Extracting stamp from image fullrun_ccd7_acisf12020_pi14-548_cl_sm2.00.img.gz, (859, 636) - (926, 702) [Tue Nov 1 06:33:34 2011] Writing fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src403.gif [Tue Nov 1 06:59:04 2011] ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src403_src.evt and ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src403_bgd.evt exist, delete to re-create [Tue Nov 1 06:59:05 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src403_src.evt.gz[events] = 2814 counts [Tue Nov 1 06:59:05 2011] Mean chipx,y = (379.29, 654.19) [Tue Nov 1 06:59:05 2011] Mean tdetx,y = (4296.29, 2356.19) [Tue Nov 1 06:59:05 2011] chipx,y range = (358.00-402.00, 633.00-675.00) [Tue Nov 1 06:59:06 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src403_bgd.evt.gz[events] = 11840 counts [Tue Nov 1 06:59:06 2011] ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src403_src.img and ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src403_bgd.img exist, delete to re-create [Tue Nov 1 06:59:06 2011] ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src403_src.pi and ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src403_bgd.pi exist, delete to re-create [Tue Nov 1 06:59:06 2011] Not generating rmf since RequireSpatial is true but spatial fitting not done [Tue Nov 1 06:59:09 2011] ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src403_src.lc and ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src403_bgd.lc exist, delete to re-create [Tue Nov 1 07:31:51 2011] Keeping rmf generated by specextract [Tue Nov 1 07:31:51 2011] 230.428 [Tue Nov 1 07:33:04 2011] Updating aperture counts using extracted products [Tue Nov 1 07:33:04 2011] Error reading totcts from fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src403_src.pi.gz [Tue Nov 1 07:33:54 2011] Calculating source flux in energy range 0.30-8.00 [Tue Nov 1 07:33:54 2011] Using photon index=1.80, rate=0.0774, arf fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src403.arf [Tue Nov 1 07:33:54 2011] Assuming count rate is from the 0.20-8.00 bandpass [Tue Nov 1 07:33:54 2011] Updating source flux to 7.2e-13 [Tue Nov 1 07:34:39 2011] Simple spatial fitting not done (or not done successfully), skipping spectral fitting