[Tue Nov 1 06:13:55 2011] Detection parameters: Position = (1072.4, 528.5) = 23 23 6.92 58 47 42.3 Extent = 0.9" x 0.8", rotation angle = 37 degrees Source counts = 439.0 +/- 29.7 Background counts = 442.0 Rate = 0.02 +/- 0.001 [Tue Nov 1 06:17:09 2011] Off-axis axis estimate = 1.93' [Tue Nov 1 06:28:25 2011] Using EEF radius (= 0.42 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:28:25 2011] Initial guess for spatial extent in simple fitting = 0.42" [Tue Nov 1 06:28:25 2011] source mask rpix=0.9, npix_max = 7, mask sum = 9, frac = 1.214 [Tue Nov 1 06:28:25 2011] Giving source the simple spatial ID 265 for pass 0, mean size = 0.42" [Tue Nov 1 06:29:25 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:29:25 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:29:25 2011] Assessing source extent using major [Tue Nov 1 06:29:25 2011] Source does appear to be extended [Tue Nov 1 06:29:25 2011] Computing asymmetry using major and minor axis, asym = 1.07 [Tue Nov 1 06:30:41 2011] Using EEF radius (= 0.42 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:30:41 2011] Initial guess for spatial extent in simple fitting = 0.42" [Tue Nov 1 06:30:41 2011] source mask rpix=0.9, npix_max = 7, mask sum = 9, frac = 1.214 [Tue Nov 1 06:30:41 2011] Giving source the simple spatial ID 265 for pass 1, mean size = 0.42" [Tue Nov 1 06:31:48 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:31:48 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:31:48 2011] Assessing source extent using major [Tue Nov 1 06:31:48 2011] Source does appear to be extended [Tue Nov 1 06:31:48 2011] Computing asymmetry using major and minor axis, asym = 1.07 [Tue Nov 1 06:33:27 2011] Not overwriting source region fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src265_src.reg [Tue Nov 1 06:33:27 2011] Extracting stamp from image fullrun_ccd7_acisf12020_pi14-548_cl_sm2.00.img.gz, (1032, 488) - (1113, 569) [Tue Nov 1 06:33:27 2011] Writing fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src265.gif [Tue Nov 1 06:51:01 2011] ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src265_src.evt and ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src265_bgd.evt exist, delete to re-create [Tue Nov 1 06:51:01 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src265_src.evt.gz[events] = 629 counts [Tue Nov 1 06:51:01 2011] Mean chipx,y = (167.83, 739.02) [Tue Nov 1 06:51:01 2011] Mean tdetx,y = (4084.83, 2441.02) [Tue Nov 1 06:51:01 2011] chipx,y range = (147.00-193.00, 716.00-761.00) [Tue Nov 1 06:51:01 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src265_bgd.evt.gz[events] = 3275 counts [Tue Nov 1 06:51:01 2011] ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src265_src.img and ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src265_bgd.img exist, delete to re-create [Tue Nov 1 06:51:01 2011] ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src265_src.pi and ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src265_bgd.pi exist, delete to re-create [Tue Nov 1 06:51:01 2011] Not generating rmf since RequireSpatial is true but spatial fitting not done [Tue Nov 1 06:51:04 2011] ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src265_src.lc and ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src265_bgd.lc exist, delete to re-create [Tue Nov 1 07:31:40 2011] Keeping rmf generated by specextract [Tue Nov 1 07:31:41 2011] 226.67 [Tue Nov 1 07:32:57 2011] Updating aperture counts using extracted products [Tue Nov 1 07:32:57 2011] Error reading totcts from fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src265_src.pi.gz [Tue Nov 1 07:33:46 2011] Calculating source flux in energy range 0.30-8.00 [Tue Nov 1 07:33:46 2011] Using photon index=1.80, rate=0.0196, arf fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src265.arf [Tue Nov 1 07:33:46 2011] Assuming count rate is from the 0.20-8.00 bandpass [Tue Nov 1 07:33:46 2011] Updating source flux to 1.8e-13 [Tue Nov 1 07:34:39 2011] Simple spatial fitting not done (or not done successfully), skipping spectral fitting