[Tue Nov 1 06:13:55 2011] Detection parameters: Position = (740.4, 527.6) = 23 23 27.94 58 47 41.8 Extent = 0.5" x 0.5", rotation angle = 126 degrees Source counts = 431.1 +/- 35.4 Background counts = 820.9 Rate = 0.02 +/- 0.002 [Tue Nov 1 06:17:09 2011] Off-axis axis estimate = 1.24' [Tue Nov 1 06:28:25 2011] Using EEF radius (= 0.38 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:28:25 2011] Initial guess for spatial extent in simple fitting = 0.38" [Tue Nov 1 06:28:25 2011] source mask rpix=0.8, npix_max = 6, mask sum = 9, frac = 1.378 [Tue Nov 1 06:28:25 2011] Giving source the simple spatial ID 264 for pass 0, mean size = 0.38" [Tue Nov 1 06:29:25 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:29:25 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:29:25 2011] Assessing source extent using major [Tue Nov 1 06:29:25 2011] Source does appear to be extended [Tue Nov 1 06:29:25 2011] Computing asymmetry using major and minor axis, asym = 1.03 [Tue Nov 1 06:30:41 2011] Using EEF radius (= 0.38 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:30:41 2011] Initial guess for spatial extent in simple fitting = 0.38" [Tue Nov 1 06:30:41 2011] source mask rpix=0.8, npix_max = 6, mask sum = 9, frac = 1.378 [Tue Nov 1 06:30:41 2011] Giving source the simple spatial ID 264 for pass 1, mean size = 0.38" [Tue Nov 1 06:31:48 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:31:48 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:31:48 2011] Assessing source extent using major [Tue Nov 1 06:31:48 2011] Source does appear to be extended [Tue Nov 1 06:31:48 2011] Computing asymmetry using major and minor axis, asym = 1.03 [Tue Nov 1 06:33:27 2011] Not overwriting source region fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src264_src.reg [Tue Nov 1 06:33:27 2011] Extracting stamp from image fullrun_ccd7_acisf12020_pi14-548_cl_sm2.00.img.gz, (717, 504) - (763, 551) [Tue Nov 1 06:33:27 2011] Writing fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src264.gif [Tue Nov 1 06:50:57 2011] ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src264_src.evt and ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src264_bgd.evt exist, delete to re-create [Tue Nov 1 06:50:58 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src264_src.evt.gz[events] = 1145 counts [Tue Nov 1 06:50:58 2011] Mean chipx,y = (334.36, 450.63) [Tue Nov 1 06:50:58 2011] Mean tdetx,y = (4251.36, 2152.63) [Tue Nov 1 06:50:58 2011] chipx,y range = (315.00-363.00, 431.00-471.00) [Tue Nov 1 06:50:58 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src264_bgd.evt.gz[events] = 2482 counts [Tue Nov 1 06:50:58 2011] ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src264_src.img and ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src264_bgd.img exist, delete to re-create [Tue Nov 1 06:50:58 2011] ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src264_src.pi and ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src264_bgd.pi exist, delete to re-create [Tue Nov 1 06:50:58 2011] Not generating rmf since RequireSpatial is true but spatial fitting not done [Tue Nov 1 06:51:01 2011] ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src264_src.lc and ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src264_bgd.lc exist, delete to re-create [Tue Nov 1 07:31:40 2011] Keeping rmf generated by specextract [Tue Nov 1 07:31:40 2011] 233.101 [Tue Nov 1 07:32:57 2011] Updating aperture counts using extracted products [Tue Nov 1 07:32:57 2011] Error reading totcts from fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src264_src.pi.gz [Tue Nov 1 07:33:46 2011] Calculating source flux in energy range 0.30-8.00 [Tue Nov 1 07:33:46 2011] Using photon index=1.80, rate=0.0193, arf fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src264.arf [Tue Nov 1 07:33:46 2011] Assuming count rate is from the 0.20-8.00 bandpass [Tue Nov 1 07:33:46 2011] Updating source flux to 1.8e-13 [Tue Nov 1 07:34:39 2011] Simple spatial fitting not done (or not done successfully), skipping spectral fitting