[Tue Nov 1 06:13:45 2011] Detection parameters: Position = (696.4, 848.5) = 23 23 30.74 58 50 19.7 Extent = 0.5" x 0.5", rotation angle = 31 degrees Source counts = 2777.6 +/- 79.8 Background counts = 3582.4 Rate = 0.1 +/- 0.004 [Tue Nov 1 06:17:09 2011] Off-axis axis estimate = 3.66' [Tue Nov 1 06:28:25 2011] Using EEF radius (= 0.73 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:28:25 2011] Initial guess for spatial extent in simple fitting = 0.73" [Tue Nov 1 06:28:25 2011] source mask rpix=1.5, npix_max = 15, mask sum = 16, frac = 1.009 [Tue Nov 1 06:28:25 2011] Giving source the simple spatial ID 187 for pass 0, mean size = 0.73" [Tue Nov 1 06:29:25 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:29:25 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:29:25 2011] Assessing source extent using major [Tue Nov 1 06:29:25 2011] Source does appear to be extended [Tue Nov 1 06:29:25 2011] Computing asymmetry using major and minor axis, asym = 1.04 [Tue Nov 1 06:30:41 2011] Using EEF radius (= 0.73 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:30:41 2011] Initial guess for spatial extent in simple fitting = 0.73" [Tue Nov 1 06:30:41 2011] source mask rpix=1.5, npix_max = 15, mask sum = 16, frac = 1.009 [Tue Nov 1 06:30:41 2011] Giving source the simple spatial ID 187 for pass 1, mean size = 0.73" [Tue Nov 1 06:31:48 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:31:48 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:31:48 2011] Assessing source extent using major [Tue Nov 1 06:31:48 2011] Source does appear to be extended [Tue Nov 1 06:31:48 2011] Computing asymmetry using major and minor axis, asym = 1.04 [Tue Nov 1 06:33:22 2011] Not overwriting source region fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src187_src.reg [Tue Nov 1 06:33:22 2011] Extracting stamp from image fullrun_ccd7_acisf12020_pi14-548_cl_sm2.00.img.gz, (673, 825) - (720, 872) [Tue Nov 1 06:33:22 2011] Writing fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src187.gif [Tue Nov 1 06:46:01 2011] ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src187_src.evt and ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src187_bgd.evt exist, delete to re-create [Tue Nov 1 06:46:01 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src187_src.evt.gz[events] = 3706 counts [Tue Nov 1 06:46:01 2011] Mean chipx,y = (634.49, 575.01) [Tue Nov 1 06:46:01 2011] Mean tdetx,y = (4551.49, 2277.01) [Tue Nov 1 06:46:01 2011] chipx,y range = (614.00-661.00, 555.00-596.00) [Tue Nov 1 06:46:01 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src187_bgd.evt.gz[events] = 316 counts [Tue Nov 1 06:46:01 2011] ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src187_src.img and ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src187_bgd.img exist, delete to re-create [Tue Nov 1 06:46:01 2011] ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src187_src.pi and ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src187_bgd.pi exist, delete to re-create [Tue Nov 1 06:46:01 2011] Not generating rmf since RequireSpatial is true but spatial fitting not done [Tue Nov 1 06:46:04 2011] ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src187_src.lc and ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src187_bgd.lc exist, delete to re-create [Tue Nov 1 07:31:35 2011] Keeping rmf generated by specextract [Tue Nov 1 07:31:35 2011] 220.932 [Tue Nov 1 07:32:53 2011] Updating aperture counts using extracted products [Tue Nov 1 07:32:53 2011] Error reading totcts from fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src187_src.pi.gz [Tue Nov 1 07:33:41 2011] Calculating source flux in energy range 0.30-8.00 [Tue Nov 1 07:33:41 2011] Using photon index=1.80, rate=0.124, arf fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src187.arf [Tue Nov 1 07:33:41 2011] Assuming count rate is from the 0.20-8.00 bandpass [Tue Nov 1 07:33:41 2011] Updating source flux to 1.2e-12 [Tue Nov 1 07:34:39 2011] Simple spatial fitting not done (or not done successfully), skipping spectral fitting