[Tue Nov 1 06:13:36 2011] Detection parameters: Position = (789.7, 800.7) = 23 23 24.82 58 49 56.2 Extent = 0.7" x 0.7", rotation angle = 100 degrees Source counts = 3263.1 +/- 88.1 Background counts = 4499.9 Rate = 0.1 +/- 0.004 [Tue Nov 1 06:17:09 2011] Off-axis axis estimate = 3.07' [Tue Nov 1 06:28:25 2011] Using EEF radius (= 0.59 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:28:25 2011] Initial guess for spatial extent in simple fitting = 0.59" [Tue Nov 1 06:28:25 2011] source mask rpix=1.2, npix_max = 11, mask sum = 9, frac = 0.770 [Tue Nov 1 06:28:25 2011] Giving source the simple spatial ID 124 for pass 0, mean size = 0.59" [Tue Nov 1 06:29:25 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:29:25 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:29:25 2011] Assessing source extent using major [Tue Nov 1 06:29:25 2011] Source does appear to be extended [Tue Nov 1 06:29:25 2011] Computing asymmetry using major and minor axis, asym = 1.05 [Tue Nov 1 06:30:41 2011] Using EEF radius (= 0.59 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:30:41 2011] Initial guess for spatial extent in simple fitting = 0.59" [Tue Nov 1 06:30:41 2011] source mask rpix=1.2, npix_max = 11, mask sum = 9, frac = 0.770 [Tue Nov 1 06:30:41 2011] Giving source the simple spatial ID 124 for pass 1, mean size = 0.59" [Tue Nov 1 06:31:48 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:31:48 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:31:48 2011] Assessing source extent using major [Tue Nov 1 06:31:48 2011] Source does appear to be extended [Tue Nov 1 06:31:48 2011] Computing asymmetry using major and minor axis, asym = 1.05 [Tue Nov 1 06:33:16 2011] Not overwriting source region fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src124_src.reg [Tue Nov 1 06:33:16 2011] Extracting stamp from image fullrun_ccd7_acisf12020_pi14-548_cl_sm2.00.img.gz, (757, 768) - (822, 833) [Tue Nov 1 06:33:17 2011] Writing fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src124.gif [Tue Nov 1 06:42:10 2011] ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src124_src.evt and ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src124_bgd.evt exist, delete to re-create [Tue Nov 1 06:42:10 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src124_src.evt.gz[events] = 5883 counts [Tue Nov 1 06:42:10 2011] Mean chipx,y = (546.09, 632.25) [Tue Nov 1 06:42:10 2011] Mean tdetx,y = (4463.09, 2334.25) [Tue Nov 1 06:42:10 2011] chipx,y range = (523.00-574.00, 610.00-654.00) [Tue Nov 1 06:42:10 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src124_bgd.evt.gz[events] = 14838 counts [Tue Nov 1 06:42:11 2011] ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src124_src.img and ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src124_bgd.img exist, delete to re-create [Tue Nov 1 06:42:11 2011] ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src124_src.pi and ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src124_bgd.pi exist, delete to re-create [Tue Nov 1 06:42:11 2011] Not generating rmf since RequireSpatial is true but spatial fitting not done [Tue Nov 1 06:42:16 2011] ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src124_src.lc and ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src124_bgd.lc exist, delete to re-create [Tue Nov 1 07:31:31 2011] Keeping rmf generated by specextract [Tue Nov 1 07:31:31 2011] 218.668 [Tue Nov 1 07:32:49 2011] Updating aperture counts using extracted products [Tue Nov 1 07:32:50 2011] Error reading totcts from fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src124_src.pi.gz [Tue Nov 1 07:33:37 2011] Calculating source flux in energy range 0.30-8.00 [Tue Nov 1 07:33:37 2011] Using photon index=1.80, rate=0.146, arf fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src124.arf [Tue Nov 1 07:33:37 2011] Assuming count rate is from the 0.20-8.00 bandpass [Tue Nov 1 07:33:37 2011] Updating source flux to 1.4e-12 [Tue Nov 1 07:34:39 2011] Simple spatial fitting not done (or not done successfully), skipping spectral fitting