[Tue Nov 1 06:13:35 2011] Detection parameters: Position = (603.5, 746.3) = 23 23 36.62 58 49 29.4 Extent = 0.8" x 0.6", rotation angle = 48 degrees Source counts = 3132.2 +/- 77.4 Background counts = 2855.8 Rate = 0.1 +/- 0.003 [Tue Nov 1 06:17:09 2011] Off-axis axis estimate = 3.31' [Tue Nov 1 06:28:25 2011] Using EEF radius (= 0.65 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:28:25 2011] Initial guess for spatial extent in simple fitting = 0.65" [Tue Nov 1 06:28:25 2011] source mask rpix=1.3, npix_max = 13, mask sum = 9, frac = 0.683 [Tue Nov 1 06:28:25 2011] Giving source the simple spatial ID 116 for pass 0, mean size = 0.65" [Tue Nov 1 06:29:25 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:29:25 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:29:25 2011] Assessing source extent using major [Tue Nov 1 06:29:25 2011] Source does appear to be extended [Tue Nov 1 06:29:25 2011] Computing asymmetry using major and minor axis, asym = 1.38 [Tue Nov 1 06:30:41 2011] Using EEF radius (= 0.65 ")to estimate initial spatial extent for simple fitting [Tue Nov 1 06:30:41 2011] Initial guess for spatial extent in simple fitting = 0.65" [Tue Nov 1 06:30:41 2011] source mask rpix=1.3, npix_max = 13, mask sum = 9, frac = 0.683 [Tue Nov 1 06:30:41 2011] Giving source the simple spatial ID 116 for pass 1, mean size = 0.65" [Tue Nov 1 06:31:48 2011] Vigneting correction estimate = 1.000000 [Tue Nov 1 06:31:48 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Nov 1 06:31:48 2011] Assessing source extent using major [Tue Nov 1 06:31:48 2011] Source does appear to be extended [Tue Nov 1 06:31:48 2011] Computing asymmetry using major and minor axis, asym = 1.38 [Tue Nov 1 06:33:16 2011] Not overwriting source region fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src116_src.reg [Tue Nov 1 06:33:16 2011] Extracting stamp from image fullrun_ccd7_acisf12020_pi14-548_cl_sm2.00.img.gz, (566, 709) - (640, 783) [Tue Nov 1 06:33:16 2011] Writing fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src116.gif [Tue Nov 1 06:41:46 2011] ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src116_src.evt and ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src116_bgd.evt exist, delete to re-create [Tue Nov 1 06:41:46 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src116_src.evt.gz[events] = 4240 counts [Tue Nov 1 06:41:46 2011] Mean chipx,y = (592.91, 443.47) [Tue Nov 1 06:41:46 2011] Mean tdetx,y = (4509.91, 2145.47) [Tue Nov 1 06:41:46 2011] chipx,y range = (572.00-614.00, 421.00-466.00) [Tue Nov 1 06:41:46 2011] Size of ../../acisf12020/products/events/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src116_bgd.evt.gz[events] = 13934 counts [Tue Nov 1 06:41:46 2011] ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src116_src.img and ../../acisf12020/products/images/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src116_bgd.img exist, delete to re-create [Tue Nov 1 06:41:46 2011] ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src116_src.pi and ../../acisf12020/products/spectra/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src116_bgd.pi exist, delete to re-create [Tue Nov 1 06:41:46 2011] Not generating rmf since RequireSpatial is true but spatial fitting not done [Tue Nov 1 06:41:49 2011] ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src116_src.lc and ../../acisf12020/products/lightcurves/fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src116_bgd.lc exist, delete to re-create [Tue Nov 1 07:31:30 2011] Keeping rmf generated by specextract [Tue Nov 1 07:31:30 2011] 223.94 [Tue Nov 1 07:32:49 2011] Updating aperture counts using extracted products [Tue Nov 1 07:32:49 2011] Error reading totcts from fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src116_src.pi.gz [Tue Nov 1 07:33:37 2011] Calculating source flux in energy range 0.30-8.00 [Tue Nov 1 07:33:37 2011] Using photon index=1.80, rate=0.14, arf fullrun_ccd7_acisf12020_pi14-548_pass1_cl_src116.arf [Tue Nov 1 07:33:37 2011] Assuming count rate is from the 0.20-8.00 bandpass [Tue Nov 1 07:33:37 2011] Updating source flux to 1.3e-12 [Tue Nov 1 07:34:39 2011] Simple spatial fitting not done (or not done successfully), skipping spectral fitting