[Fri Oct 21 19:23:53 2011] Detection parameters: Position = (790.9, 880.5) = 0 51 21.42 -73 21 46.5 Extent = 0.8" x 0.5", rotation angle = 42 degrees Source counts = 6.0 +/- 2.8 Background counts = 2.0 Rate = 0.0003 +/- 0.0001 [Fri Oct 21 19:23:53 2011] Off-axis axis estimate = 1.36' [Fri Oct 21 19:24:29 2011] Using EEF radius (= 0.39 ")to estimate initial spatial extent for simple fitting [Fri Oct 21 19:24:29 2011] Initial guess for spatial extent in simple fitting = 0.39" [Fri Oct 21 19:24:29 2011] Spatial fitting skipped for pass 0: source has 6.0 net counts, is at off-axis angle 1.4' [Fri Oct 21 19:24:38 2011] Vigneting correction estimate = 1.000000 [Fri Oct 21 19:24:38 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Fri Oct 21 19:24:38 2011] Assessing source extent using major [Fri Oct 21 19:24:38 2011] Source does appear to be extended [Fri Oct 21 19:24:38 2011] Computing asymmetry using major and minor axis, asym = 1.68 [Fri Oct 21 19:24:38 2011] Source is asymmetric [Fri Oct 21 19:24:38 2011] Deleting source due to low Poisson probability 0.9