[Wed Oct 19 01:53:02 2011] Detection parameters: Position = (668.5, 783.5) = 5 28 4.71 -52 59 41.9 Extent = 0.5" x 0.5", rotation angle = 90 degrees Source counts = 0.7 +/- 1.0 Background counts = 0.3 Rate = 2e-05 +/- 3e-05 [Wed Oct 19 01:53:02 2011] Off-axis axis estimate = 3.52' [Wed Oct 19 02:59:35 2011] Using EEF radius (= 0.70 ")to estimate initial spatial extent for simple fitting [Wed Oct 19 02:59:35 2011] Initial guess for spatial extent in simple fitting = 0.70" [Wed Oct 19 02:59:35 2011] Spatial fitting skipped for pass 0: source has 0.7 net counts, is at off-axis angle 3.5' [Wed Oct 19 03:42:26 2011] Vigneting correction estimate = 1.000000 [Wed Oct 19 03:42:26 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Wed Oct 19 03:42:26 2011] Assessing source extent using major [Wed Oct 19 03:42:26 2011] Source does appear to be extended [Wed Oct 19 03:42:26 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Wed Oct 19 03:42:26 2011] Deleting source due to low Poisson probability 0.8