[Wed Nov 23 05:28:17 2011] Detection parameters: Position = (508.5, 886.5) = 12 15 13.59 -65 32 19.7 Extent = 0.5" x 0.5", rotation angle = 90 degrees Source counts = 20.0 +/- 5.9 Background counts = 15.0 Rate = 0.0002 +/- 7e-05 [Wed Nov 23 05:28:17 2011] Off-axis axis estimate = 5.01' [Wed Nov 23 07:57:57 2011] Using EEF radius (= 1.18 ")to estimate initial spatial extent for simple fitting [Wed Nov 23 07:57:57 2011] Initial guess for spatial extent in simple fitting = 1.18" [Wed Nov 23 07:57:57 2011] source mask rpix=2.4, npix_max = 33, mask sum = 15, frac = 0.444 [Wed Nov 23 07:57:57 2011] Skipping simple spatial due to low active detector fraction [Wed Nov 23 09:02:50 2011] Vigneting correction estimate = 1.000000 [Wed Nov 23 09:02:50 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Wed Nov 23 09:02:50 2011] Assessing source extent using major [Wed Nov 23 09:02:50 2011] Source does appear to be extended [Wed Nov 23 09:02:50 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Wed Nov 23 10:47:08 2011] Using EEF radius (= 1.18 ")to estimate initial spatial extent for simple fitting [Wed Nov 23 10:47:08 2011] Initial guess for spatial extent in simple fitting = 1.18" [Wed Nov 23 10:47:08 2011] source mask rpix=2.4, npix_max = 33, mask sum = 15, frac = 0.444 [Wed Nov 23 10:47:08 2011] Skipping simple spatial due to low active detector fraction [Wed Nov 23 11:53:37 2011] Vigneting correction estimate = 1.000000 [Wed Nov 23 11:53:37 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Wed Nov 23 11:53:37 2011] Assessing source extent using major [Wed Nov 23 11:53:37 2011] Source does appear to be extended [Wed Nov 23 11:53:37 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Wed Nov 23 12:45:50 2011] Writing source region out to fullrun_ccd3_acisf11101_pi14-548_pass1_cl_src60_src.reg [Wed Nov 23 12:45:50 2011] Extracting stamp from image fullrun_ccd3_acisf11101_pi14-548_cl_sm2.00.img.gz, (486, 864) - (531, 909) [Wed Nov 23 12:45:50 2011] Writing fullrun_ccd3_acisf11101_pi14-548_pass1_cl_src60.gif [Wed Nov 23 13:13:02 2011] Size of ../../acisf11101/products/events/fullrun_ccd3_acisf11101_pi14-548_pass1_cl_src60_src.evt.gz[events] = 65 counts [Wed Nov 23 13:13:02 2011] Mean chipx,y = (770.60, 443.72) [Wed Nov 23 13:13:02 2011] Mean tdetx,y = (4688.28, 3831.60) [Wed Nov 23 13:13:02 2011] chipx,y range = (751.00-788.00, 423.00-462.00) [Wed Nov 23 13:13:02 2011] Size of ../../acisf11101/products/events/fullrun_ccd3_acisf11101_pi14-548_pass1_cl_src60_bgd.evt.gz[events] = 561 counts [Wed Nov 23 13:13:03 2011] Not generating rmf since there are only 20 counts [Wed Nov 23 13:13:03 2011] arf not found, will run specextract [Wed Nov 23 13:13:32 2011] ../../acisf11101/products/spectra/fullrun_ccd3_acisf11101_pi14-548_pass1_cl_src60.warf not found [Wed Nov 23 13:13:32 2011] ../../acisf11101/products/spectra/fullrun_ccd3_acisf11101_pi14-548_pass1_cl_src60.wrmf not found [Wed Nov 23 13:13:32 2011] Removal of ../../acisf11101/products/spectra/fullrun_ccd3_acisf11101_pi14-548_pass1_cl_src60.soff failed [Wed Nov 23 13:16:11 2011] Spectrum 60 has only 20 counts, deleting rmf [Wed Nov 23 13:16:11 2011] 180.635 [Wed Nov 23 13:16:19 2011] Updating aperture counts using extracted products [Wed Nov 23 13:16:19 2011] Error reading totcts from fullrun_ccd3_acisf11101_pi14-548_pass1_cl_src60_src.pi.gz [Wed Nov 23 13:16:19 2011] Calculating source flux in energy range 0.30-8.00 [Wed Nov 23 13:16:19 2011] Using photon index=1.80, rate=0.000225, arf fullrun_ccd3_acisf11101_pi14-548_pass1_cl_src60.arf [Wed Nov 23 13:16:19 2011] Assuming count rate is from the 0.20-8.00 bandpass [Wed Nov 23 13:16:19 2011] Updating source flux to 3.2e-15 [Wed Nov 23 13:17:36 2011] Simple spatial fitting not done (or not done successfully), skipping spectral fitting