[Thu Oct 27 23:26:12 2011] Detection parameters: Position = (1375.8, 891.3) = 0 25 28.36 64 7 51.1 Extent = 0.6" x 0.5", rotation angle = 150 degrees Source counts = -0.2 +/- 4.2 Background counts = 18.2 Rate = -4e-06 +/- 0.0001 [Thu Oct 27 23:26:19 2011] Off-axis axis estimate = 0.96' [Thu Oct 27 23:35:28 2011] Using EEF radius (= 0.38 ")to estimate initial spatial extent for simple fitting [Thu Oct 27 23:35:28 2011] Initial guess for spatial extent in simple fitting = 0.38" [Thu Oct 27 23:35:28 2011] Spatial fitting skipped for pass 0: source has -0.2 net counts, is at off-axis angle 1.0' [Thu Oct 27 23:36:35 2011] Vigneting correction estimate = 1.000000 [Thu Oct 27 23:36:35 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Thu Oct 27 23:36:35 2011] Assessing source extent using major [Thu Oct 27 23:36:35 2011] Source does appear to be extended [Thu Oct 27 23:36:35 2011] Computing asymmetry using major and minor axis, asym = 1.27 [Thu Oct 27 23:36:35 2011] Deleting source due to low Poisson probability 0.5