[Wed Oct 26 08:11:18 2011] Detection parameters: Position = (600.5, 1096.5) = 0 25 15.01 64 5 27.0 Extent = 0.5" x 0.5", rotation angle = 90 degrees Source counts = 67.4 +/- 15.6 Background counts = 174.6 Rate = 0.0006 +/- 0.0001 [Wed Oct 26 08:12:08 2011] Off-axis axis estimate = 3.15' [Wed Oct 26 08:31:02 2011] Using EEF radius (= 0.61 ")to estimate initial spatial extent for simple fitting [Wed Oct 26 08:31:02 2011] Initial guess for spatial extent in simple fitting = 0.61" [Wed Oct 26 08:31:02 2011] source mask rpix=1.2, npix_max = 12, mask sum = 5, frac = 0.411 [Wed Oct 26 08:31:02 2011] Skipping simple spatial due to low active detector fraction [Wed Oct 26 08:32:20 2011] Vigneting correction estimate = 1.000000 [Wed Oct 26 08:32:20 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Wed Oct 26 08:32:20 2011] Assessing source extent using major [Wed Oct 26 08:32:20 2011] Source does appear to be extended [Wed Oct 26 08:32:20 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Wed Oct 26 08:32:20 2011] Deleting source due to low Poisson probability 0.9