[Mon Sep 26 07:52:05 2011] Detection parameters: Position = (700.5, 283.5) = 0 25 40.96 64 10 11.9 Extent = 0.5" x 0.5", rotation angle = 90 degrees Source counts = 31.8 +/- 15.6 Background counts = 211.2 Rate = 0.0003 +/- 0.0001 [Mon Sep 26 07:52:35 2011] Off-axis axis estimate = 2.66' [Mon Sep 26 08:13:59 2011] Using EEF radius (= 0.52 ")to estimate initial spatial extent for simple fitting [Mon Sep 26 08:13:59 2011] Initial guess for spatial extent in simple fitting = 0.52" [Mon Sep 26 08:13:59 2011] source mask rpix=1.1, npix_max = 9, mask sum = 1, frac = 0.104 [Mon Sep 26 08:13:59 2011] Skipping simple spatial due to low active detector fraction [Mon Sep 26 08:16:01 2011] Vigneting correction estimate = 1.000000 [Mon Sep 26 08:16:01 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Mon Sep 26 08:16:01 2011] Assessing source extent using major [Mon Sep 26 08:16:01 2011] Source does appear to be extended [Mon Sep 26 08:16:01 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Mon Sep 26 08:16:01 2011] Deleting source due to low Poisson probability 0.7