[Mon Sep 26 07:51:42 2011] Detection parameters: Position = (908.9, 161.8) = 0 25 25.27 64 9 12.1 Extent = 0.5" x 0.5", rotation angle = 39 degrees Source counts = 1.2 +/- 4.5 Background counts = 18.8 Rate = 1e-05 +/- 4e-05 [Mon Sep 26 07:52:35 2011] Off-axis axis estimate = 0.76' [Mon Sep 26 08:13:59 2011] Using EEF radius (= 0.38 ")to estimate initial spatial extent for simple fitting [Mon Sep 26 08:13:59 2011] Initial guess for spatial extent in simple fitting = 0.38" [Mon Sep 26 08:13:59 2011] Spatial fitting skipped for pass 0: source has 1.2 net counts, is at off-axis angle 0.8' [Mon Sep 26 08:16:01 2011] Vigneting correction estimate = 1.000000 [Mon Sep 26 08:16:01 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Mon Sep 26 08:16:01 2011] Assessing source extent using major [Mon Sep 26 08:16:01 2011] Source does appear to be extended [Mon Sep 26 08:16:01 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Mon Sep 26 08:16:01 2011] Deleting source due to low Poisson probability 0.5