RXTE Galactic Center Observation
Observation Date: | 1999-10-15 |
Mission Day: | 2113g |
Modified Julian Day: | 51466.295 |
Mission times: | 182588673.00- 182597943.00 |
Scan type: | regular |
Main Page: | Observation List | Source List |
Observation Page: | Top | Commentary | Sources | Scan Light Curves |
Map Page: | Reconstructed Model | Residuals |
Scan Light Curves: | Parts 1 | 2 | 3 | 4 |
Craig Markwardt writes: Here is a brief report on the galactic bulge scans of 15 Oct 1999, primarily north-south in direction. * GRS 1747-312 (= Terzan 6) has declined very rapidly since the previous observation, to a level of about 35 ct/s/5PCU (2-13 keV). * The rapid burster continues to decline, again more slowly than the previous outburst. Craig Craig Markwardt writes: [ This is an excerpt from day 2117, the next week ] * a faint source I forgot to mention last week, designated XTE J1805-295, reached a peak flux of 33+/-3 ct/s. The best-fit position was RA=271.4045, DEC=-29.5209. Again, there are no compelling nearby known sources. This was a faint source which was undetectable in this most recent observation.
Source | Time (MJD) | RA (2000) | DEC (2000) | Rate (ct/s/5PCU) | Error (ct/s/5PCU) | Bkg (ct/s/5PCU) |
---|---|---|---|---|---|---|
1E1740.7-2942 | 51466.326 | 265.9604 | -29.75 | 222.25 | 24.69 | 283.17 |
1E1743.1-2843 | 51466.330 | 266.5792 | -28.72 | 360.67 | 67.37 | 33.76 |
2E1746.7-3225 | 51466.331 | 267.5144 | -32.43 | 1.55 | 7.64 | 20.88 |
2S1742-294 | 51466.328 | 266.5230 | -29.52 | 343.13 | 32.01 | 315.22 |
2S1803-245 | 51466.385 | 271.7090 | -24.59 | 9.45 | 5.21 | 13.18 |
4U_1728-34 | 51466.311 | 262.9920 | -33.83 | 640.74 | 18.95 | 385.06 |
4U_1820-30 | 51466.389 | 275.9280 | -30.37 | 2826.41 | 70.78 | 2.74 |
4U_1820-30 | 51466.392 | 275.9280 | -30.37 | 3038.86 | 28.38 | 2.74 |
4U_1820-30 | 51466.396 | 275.9280 | -30.37 | 2717.82 | 46.92 | 2.74 |
A1744-361 | 51466.323 | 267.0800 | -36.12 | 2.01 | 1.73 | 15.47 |
AX_J1749.1-2639 | 51466.357 | 267.3000 | -26.65 | -33.09 | 28.75 | 2128.21 |
EXO_1722-363 | 51466.303 | 261.4810 | -36.41 | 8.63 | 6.42 | 22.46 |
EXO_1742-326 | 51466.325 | 266.3690 | -32.69 | 22.60 | 7.06 | 26.64 |
EXO_1745-248 | 51466.366 | 267.0208 | -24.78 | 5.20 | 2.67 | 16.11 |
GCRT_J1745-3009 | 51466.327 | 266.2708 | -30.16 | 13.93 | 13.10 | 330.22 |
GCRT_J1746-2757 | 51466.335 | 266.5417 | -27.95 | 26.30 | 12.32 | 86.15 |
GRS_1734-292 | 51466.321 | 264.3533 | -29.18 | 43.23 | 5.49 | 23.30 |
GRS_1747-312 | 51466.341 | 267.6900 | -31.29 | 38.25 | 12.48 | 5.69 |
GRS_1758-258 | 51466.378 | 270.3025 | -25.74 | 186.79 | 16.26 | 2815.81 |
GS_1826-238 | 51466.401 | 277.3623 | -23.79 | 365.25 | 1.70 | 3.08 |
GX_1+4 | 51466.316 | 263.0090 | -24.75 | 62.66 | 10.31 | 6.77 |
GX_1+4 | 51466.322 | 263.0090 | -24.75 | 125.86 | 9.58 | 6.77 |
GX_3+1 | 51466.331 | 266.9830 | -26.56 | 3052.82 | 44.89 | 4.05 |
GX_3+1 | 51466.366 | 266.9830 | -26.56 | 2971.00 | 53.19 | 4.05 |
GX_5-1 | 51466.377 | 270.2840 | -25.08 | 9860.50 | 47.23 | 70.42 |
GX_5-1 | 51466.381 | 270.2840 | -25.08 | 9922.82 | 85.88 | 70.42 |
H1743-322 | 51466.326 | 266.5700 | -32.24 | 22.62 | 5.51 | 27.33 |
IGR_J17191-2821 | 51466.303 | 259.7700 | -28.35 | 3.69 | 2.68 | 3.56 |
IGR_J17331-2406 | 51466.323 | 263.2833 | -24.11 | 6.36 | 1.74 | 37.91 |
IGR_J17375-3022 | 51466.319 | 264.3946 | -30.38 | 1.53 | 7.59 | 33.17 |
IGR_J17497-2821 | 51466.351 | 267.4041 | -28.36 | 51.30 | 19.03 | 46.90 |
IGR_J17511-3057 | 51466.342 | 267.7875 | -30.96 | -30.47 | 19.20 | 61.91 |
IGR_J17586-2129 | 51466.380 | 269.6440 | -21.39 | 5.51 | 3.36 | 36.93 |
K1724-356 | 51466.305 | 261.9133 | -35.73 | -3.78 | 3.20 | 27.29 |
KS_1731-260 | 51466.321 | 263.5539 | -26.09 | 460.34 | 10.07 | 8.62 |
KS_1732-273 | 51466.321 | 263.9958 | -27.44 | 2.40 | 6.18 | 43.27 |
KS_1741-293 | 51466.328 | 266.2042 | -29.35 | 176.95 | 57.41 | 402.04 |
MXB_1730-33 | 51466.312 | 263.3498 | -33.39 | 837.90 | 15.86 | 303.33 |
NGC_6440 | 51466.373 | 267.2195 | -20.36 | -33.66 | 20.13 | 6.13 |
OPH_CLU | 51466.302 | 258.1580 | -23.39 | 283.42 | 2.53 | 2.68 |
RXS_J172006.1 | 51466.300 | 260.0254 | -31.28 | 35.56 | 5.26 | 5.93 |
RXS_J172525.5 | 51466.305 | 261.3563 | -32.95 | 38.40 | 3.45 | 15.04 |
RXS_J173251.1 | 51466.311 | 263.2129 | -34.79 | 22.71 | 4.64 | 41.04 |
RXS_J175428.3 | 51466.370 | 268.6179 | -26.34 | 9.36 | 6.38 | 33.23 |
RXS_J180326.2 | 51466.380 | 270.8417 | -25.27 | 2.86 | 19.73 | 4179.15 |
RXS_J180824.5 | 51466.387 | 272.1021 | -23.15 | 8.04 | 2.15 | 13.23 |
R_1832-330 | 51466.397 | 278.9317 | -32.99 | 107.90 | 5.63 | 2.67 |
SAXJ1747.0-2853 | 51466.336 | 266.7879 | -28.88 | 70.43 | 36.77 | 309.04 |
SAXJ1750.8-2900 | 51466.348 | 267.6000 | -29.03 | 34.44 | 6.84 | 49.69 |
SAXJ1753.5-2349 | 51466.373 | 268.3917 | -23.82 | 2.40 | 2.88 | 16.62 |
SAXJ1806.5-2215 | 51466.387 | 271.6417 | -22.25 | 1.14 | 0.78 | 20.31 |
SAXJ1808.4-3658 | 51466.369 | 272.1208 | -36.98 | -0.98 | 0.58 | 2.71 |
SAXJ1808.4-365P | 51466.369 | 271.1200 | -35.50 | 1.23 | 2.39 | 2.96 |
SAXJ1810.8-2609 | 51466.387 | 272.6850 | -26.15 | 3.34 | 2.58 | 8.19 |
SGR_1806-20 | 51466.394 | 272.1642 | -20.41 | 18.35 | 5.90 | 26.61 |
SGR_A | 51466.328 | 266.4000 | -29.00 | -177.10 | 83.22 | 589.15 |
SLX_1735-269 | 51466.323 | 264.5647 | -27.00 | 107.27 | 6.10 | 15.25 |
SLX_1737-282 | 51466.324 | 265.2360 | -28.31 | 14.23 | 17.08 | 55.56 |
SLX_1744-300 | 51466.329 | 266.8580 | -30.04 | 191.66 | 15.52 | 190.43 |
SLX_1746-331 | 51466.328 | 267.4608 | -33.20 | 24.99 | 4.78 | 11.34 |
SW_J1729.9-3437 | 51466.308 | 262.5375 | -34.61 | -2.37 | 6.95 | 102.22 |
SW_J1756.9-2508 | 51466.373 | 269.2380 | -25.11 | -11.65 | 4.68 | 502.01 |
TERZAN_2 | 51466.310 | 261.8880 | -30.80 | 319.33 | 7.72 | 13.57 |
WGAJ1715.3-2635 | 51466.302 | 258.8370 | -26.60 | 4.83 | 2.31 | 2.95 |
XTE_J1710-281 | 51466.295 | 257.5500 | -28.12 | 17.60 | 3.63 | 2.91 |
XTE_J1710-281P | 51466.296 | 258.5500 | -28.91 | 1.72 | 2.66 | 3.57 |
XTE_J1719-291 | 51466.303 | 259.8890 | -29.06 | -3.27 | 2.62 | 5.95 |
XTE_J1719-356 | 51466.298 | 259.9700 | -35.68 | -0.24 | 2.58 | 16.25 |
XTE_J1720-318 | 51466.300 | 259.9961 | -31.75 | -5.15 | 4.77 | 26.82 |
XTE_J1723-376 | 51466.298 | 260.9000 | -37.65 | 3.38 | 2.40 | 15.56 |
XTE_J1726-283 | 51466.310 | 261.6570 | -28.30 | 4.01 | 2.85 | 7.77 |
XTE_J1728-295 | 51466.311 | 262.1570 | -29.52 | -0.36 | 3.32 | 11.89 |
XTE_J1739-285 | 51466.324 | 264.9790 | -28.48 | 48.06 | 15.92 | 34.01 |
XTE_J1739-302 | 51466.321 | 264.7500 | -30.27 | 10.09 | 7.88 | 32.28 |
XTE_J1743-363 | 51466.319 | 265.7415 | -36.33 | 10.90 | 0.93 | 7.65 |
XTE_J1744-230 | 51466.348 | 266.0350 | -23.12 | 33.43 | 6.19 | 8.68 |
XTE_J1747-274 | 51466.341 | 266.9095 | -27.44 | 30.04 | 14.23 | 307.75 |
XTE_J1748-288 | 51466.340 | 267.0210 | -28.47 | -104.00 | 45.34 | 269.64 |
XTE_J1751-305 | 51466.344 | 267.8062 | -30.62 | 24.49 | 13.14 | 13.26 |
XTE_J1752-223 | 51466.373 | 268.0440 | -22.32 | -3.05 | 1.98 | 12.06 |
XTE_J1752-280 | 51466.366 | 268.2000 | -28.00 | 25.07 | 4.98 | 31.58 |
XTE_J1755-312 | 51466.355 | 268.7820 | -31.16 | 47.48 | 5.46 | 18.08 |
XTE_J1756-342 | 51466.348 | 269.0228 | -34.21 | 9.34 | 2.22 | 5.30 |
XTE_J1757-306 | 51466.368 | 269.4130 | -30.66 | 30.09 | 3.90 | 20.84 |
XTE_J1759-220 | 51466.380 | 269.9404 | -22.03 | 0.60 | 2.23 | 20.78 |
XTE_J1805-295 | 51466.377 | 271.4045 | -29.52 | 29.81 | 7.13 | 12.31 |
XTE_J1807-294 | 51466.378 | 271.7441 | -29.40 | 7.76 | 7.16 | 26.58 |
XTE_J1810-189 | 51466.394 | 272.5863 | -19.07 | 13.33 | 36.05 | 36.44 |
XTE_J1810-197 | 51466.394 | 272.4630 | -19.73 | -8.66 | 6.75 | 43.83 |
XTE_J1812-230 | 51466.394 | 273.2000 | -23.00 | 3.21 | 2.70 | 10.32 |
XTE_J1814-338 | 51466.378 | 273.4126 | -33.77 | 9.75 | 3.82 | 2.78 |
XTE_J1817-330 | 51466.383 | 274.4250 | -33.02 | -0.27 | 1.95 | 2.76 |
XTE_J1818-245 | 51466.394 | 274.6050 | -24.54 | 7.14 | 3.50 | 5.54 |
XTE_J1819-254 | 51466.394 | 274.8300 | -25.41 | 2.55 | 2.95 | 4.99 |
XTE_J1819-254P | 51466.390 | 273.8300 | -26.41 | 11.16 | 3.75 | 5.26 |
![]() |
Legend -------------------------- 1 - XTE J1710-281 2 - XTE J1710-281P 3 - OPH CLU 5 - WGAJ1715.3-2635 6 - IGR J17191-2821 10 - RXS J172006.1 11 - XTE J1723-376 12 - EXO 1722-363 13 - RXS J172525.5 14 - XTE J1726-283 15 - TERZAN 2 18 - 4U 1728-34 19 - GX 1+4 20 - RXS J173251.1 22 - MXB 1730-33 |
![]() |
Legend -------------------------- 19 - GX 1+4 21 - IGR J17331-2406 25 - KS 1731-260 26 - KS 1732-273 27 - GRS 1734-292 28 - IGR J17375-3022 30 - SLX 1735-269 31 - XTE J1739-302 32 - XTE J1739-285 33 - SLX 1737-282 35 - XTE J1743-363 36 - 1E1740.7-2942 37 - XTE J1744-230 38 - KS 1741-293 39 - GCRT J1745-3009 40 - EXO 1742-326 42 - 2S1742-294 43 - GCRT J1746-2757 44 - 1E1743.1-2843 45 - H1743-322 46 - SAXJ1747.0-2853 48 - SLX 1744-300 50 - XTE J1747-274 51 - GX 3+1 58 - IGR J17497-2821 59 - SLX 1746-331 62 - SAXJ1750.8-2900 63 - GRS 1747-312 65 - XTE J1751-305 71 - XTE J1755-312 72 - XTE J1756-342 191 - GX 1+4 |
![]() |
Legend -------------------------- 37 - XTE J1744-230 46 - SAXJ1747.0-2853 50 - XTE J1747-274 53 - EXO 1745-248 58 - IGR J17497-2821 62 - SAXJ1750.8-2900 63 - GRS 1747-312 65 - XTE J1751-305 68 - XTE J1752-280 69 - SAXJ1753.5-2349 70 - RXS J175428.3 71 - XTE J1755-312 72 - XTE J1756-342 74 - XTE J1757-306 75 - IGR J17586-2129 77 - GX 5-1 78 - GRS 1758-258 81 - RXS J180326.2 83 - XTE J1805-295 84 - XTE J1807-294 86 - 2S1803-245 96 - XTE J1814-338 192 - GX 3+1 193 - GX 5-1 |
![]() |
Legend -------------------------- 85 - SAXJ1806.5-2215 86 - 2S1803-245 87 - RXS J180824.5 90 - SGR 1806-20 92 - XTE J1810-189 93 - SAXJ1810.8-2609 95 - XTE J1812-230 100 - XTE J1818-245 101 - XTE J1819-254 102 - XTE J1819-254P 103 - 4U 1820-30 104 - GS 1826-238 105 - R 1832-330 150 - G11.2-0.3 194 - 4U 1820-30 195 - 4U 1820-30 |
Top | Maps | Commentary | Sources | Scan Light Curves
Generated automatically on Fri Mar 18 23:03:05 2011 by Craig Markwardt