RXTE Galactic Center Observation

Observation Date:1999-06-07
Mission Day:1983f
Modified Julian Day: 51336.230
Mission times: 171351089.00- 171360719.00
Scan type:cross

Main Page: Observation List | Source List
Observation Page: Top | Commentary | Sources | Scan Light Curves
Map Page: Reconstructed Model | Residuals
Scan Light Curves: Parts 1 | 2 | 3 | 4

PCA Reconstructed model on 1999-06-07 (click a source)

1E1740.7-2942 (265.96,-29.75) 1E1743.1-2843 (266.58,-28.72) 2E1746.7-3225 (267.51,-32.43) 2S1742-294 (266.52,-29.52) 2S1803-245 (271.71,-24.59) 4U 1711-34 (258.58,-34.05) 4U 1728-34 (262.99,-33.83) 4U 1746-371 (267.55,-37.05) 4U 1820-30 (275.93,-30.37) A1744-361 (267.08,-36.12) AX J1749.1-2639 (267.30,-26.65) EXO 1722-363 (261.48,-36.41) EXO 1742-326 (266.37,-32.69) EXO 1745-248 (267.02,-24.78) GCRT J1745-3009 (266.27,-30.16) GCRT J1746-2757 (266.54,-27.95) GRS 1734-292 (264.35,-29.18) GRS 1747-312 (267.69,-31.29) GRS 1758-258 (270.30,-25.74) GS 1826-238 (277.36,-23.79) GX 1+4 (263.01,-24.75) GX 3+1 (266.98,-26.56) GX 5-1 (270.28,-25.08) GX 9+1 (270.38,-20.53) H1743-322 (266.57,-32.24) IGR J17191-2821 (259.77,-28.35) IGR J17331-2406 (263.28,-24.11) IGR J17375-3022 (264.39,-30.38) IGR J17497-2821 (267.40,-28.36) IGR J17511-3057 (267.79,-30.96) IGR J17586-2129 (269.64,-21.39) K1724-356 (261.91,-35.73) KS 1731-260 (263.55,-26.09) KS 1732-273 (264.00,-27.44) KS 1741-293 (266.20,-29.35) MXB 1730-33 (263.35,-33.39) OPH CLU (258.16,-23.39) R 1832-330 (278.93,-32.99) RXJ1709.5-263 (257.38,-26.66) RXS J172006.1 (260.03,-31.28) RXS J172525.5 (261.36,-32.95) RXS J173251.1 (263.21,-34.79) RXS J175428.3 (268.62,-26.34) RXS J180326.2 (270.84,-25.27) RXS J180824.5 (272.10,-23.15) SAXJ1747.0-2853 (266.79,-28.88) SAXJ1750.8-2900 (267.60,-29.03) SAXJ1753.5-2349 (268.39,-23.82) SAXJ1802.7-2017 (270.67,-20.29) SAXJ1806.5-2215 (271.64,-22.25) SAXJ1808.4-3658 (272.12,-36.98) SAXJ1808.4-365P (271.12,-35.50) SAXJ1810.8-2609 (272.69,-26.15) SGR 1806-20 (272.16,-20.41) SGR A (266.40,-29.00) SLX 1735-269 (264.56,-27.00) SLX 1737-282 (265.24,-28.31) SLX 1744-300 (266.86,-30.04) SLX 1746-331 (267.46,-33.20) SW J1729.9-3437 (262.54,-34.61) TERZAN 2 (261.89,-30.80) WGAJ1715.3-2635 (258.84,-26.60) XTE J1710-281 (257.55,-28.12) XTE J1710-281P (258.55,-28.91) XTE J1719-291 (259.89,-29.06) XTE J1719-356 (259.97,-35.68) XTE J1720-318 (260.00,-31.75) XTE J1723-376 (260.90,-37.65) XTE J1726-283 (261.66,-28.30) XTE J1728-295 (262.16,-29.52) XTE J1734-234 (263.53,-23.36) XTE J1737-376 (264.50,-37.77) XTE J1739-285 (264.98,-28.48) XTE J1739-302 (264.75,-30.27) XTE J1743-363 (265.74,-36.33) XTE J1744-230 (266.04,-23.12) XTE J1747-274 (266.91,-27.44) XTE J1748-288 (267.02,-28.47) XTE J1751-305 (267.81,-30.62) XTE J1752-223 (268.04,-22.32) XTE J1752-280 (268.20,-28.00) XTE J1755-312 (268.78,-31.16) XTE J1756-342 (269.02,-34.21) XTE J1757-306 (269.41,-30.66) XTE J1759-220 (269.94,-22.03) XTE J1805-295 (271.40,-29.52) XTE J1807-294 (271.74,-29.40) XTE J1812-230 (273.20,-23.00) XTE J1814-338 (273.41,-33.77) XTE J1817-330 (274.43,-33.02) XTE J1818-245 (274.61,-24.54) XTE J1819-254 (274.83,-25.41) XTE J1819-254P (273.83,-26.41)

Commentary

Craig Markwardt writes:

Not much to report for the galactic bulge scans of 7 Jun 1999.  These
were "cross" scans, primarily in the East-West direction.

 * after peaking at about 2200 ct/s/5PCU last observation (3 Jun), 4U
   1728-34 has dropped again to around 1000 ct/s.

Other than that, there are no new bright sources.  Existing sources
are pretty much steady.  It must be a lazy summertime in the galactic
center as well as here.

I have a slightly improved source model that adds a few new faint
sources, which I will put on the web page soon.

Craig

Known Sources: ASCII table

SourceTime (MJD)RA (2000)DEC (2000)Rate (ct/s/5PCU)Error (ct/s/5PCU)Bkg (ct/s/5PCU)
1E1740.7-2942 51336.287 265.9604 -29.75 261.75 27.77 259.40
1E1743.1-2843 51336.302 266.5792 -28.72 -27.33 72.88 383.28
2E1746.7-3225 51336.254 267.5144 -32.43 34.65 5.01 15.17
2S1742-294 51336.289 266.5230 -29.52 215.72 44.16 455.44
2S1803-245 51336.316 271.7090 -24.59 -7.91 4.80 14.83
4U_1711-34 51336.253 258.5800 -34.05 24.92 0.94 9.38
4U_1728-34 51336.252 262.9920 -33.83 1021.97 17.62 40.26
4U_1746-371 51336.232 267.5523 -37.05 307.61 9.09 4.71
4U_1820-30 51336.250 275.9280 -30.37 2777.18 44.37 3.10
4U_1820-30 51336.257 275.9280 -30.37 3212.96 28.07 3.10
A1744-361 51336.237 267.0800 -36.12 9.49 3.72 12.74
AX_J1749.1-2639 51336.312 267.3000 -26.65 134.50 28.09 2021.27
EXO_1722-363 51336.239 261.4810 -36.41 -2.30 2.34 20.58
EXO_1742-326 51336.254 266.3690 -32.69 36.78 5.52 20.60
EXO_1745-248 51336.321 267.0208 -24.78 -5.07 2.67 16.47
GCRT_J1745-3009 51336.276 266.2708 -30.16 35.01 18.65 359.23
GCRT_J1746-2757 51336.305 266.5417 -27.95 109.48 22.57 31.88
GRS_1734-292 51336.302 264.3533 -29.18 44.95 4.95 21.91
GRS_1747-312 51336.259 267.6900 -31.29 79.79 15.26 8.93
GRS_1758-258 51336.312 270.3025 -25.74 221.99 18.40 3877.55
GS_1826-238 51336.314 277.3623 -23.79 350.84 1.95 3.44
GX_1+4 51336.320 263.0090 -24.75 145.02 91.85 15.97
GX_1+4 51336.324 263.0090 -24.75 446.43 10.66 15.97
GX_1+4 51336.327 263.0090 -24.75 108.01 7.71 15.97
GX_3+1 51336.309 266.9830 -26.56 2904.78 54.47 117.47
GX_3+1 51336.314 266.9830 -26.56 2826.76 31.62 117.47
GX_5-1 51336.313 270.2840 -25.08 13241.04 104.43 126.66
GX_5-1 51336.317 270.2840 -25.08 13584.00 57.91 126.66
GX_9+1 51336.335 270.3846 -20.53 7320.52 80.55 317.23
H1743-322 51336.255 266.5700 -32.24 8.07 6.79 38.82
IGR_J17191-2821 51336.310 259.7700 -28.35 2.42 3.80 4.02
IGR_J17331-2406 51336.329 263.2833 -24.11 39.93 7.27 32.48
IGR_J17375-3022 51336.282 264.3946 -30.38 8.32 6.78 30.15
IGR_J17497-2821 51336.302 267.4041 -28.36 37.90 23.45 73.75
IGR_J17511-3057 51336.262 267.7875 -30.96 -22.34 26.87 84.64
IGR_J17586-2129 51336.333 269.6440 -21.39 -5.24 4.42 38.80
K1724-356 51336.243 261.9133 -35.73 -15.88 7.01 25.62
KS_1731-260 51336.317 263.5539 -26.09 1076.14 13.62 9.00
KS_1732-273 51336.310 263.9958 -27.44 3.58 4.66 68.79
KS_1741-293 51336.291 266.2042 -29.35 86.54 74.55 520.80
MXB_1730-33 51336.253 263.3498 -33.39 12.74 8.65 462.81
OPH_CLU 51336.333 258.1580 -23.39 511.23 15.17 3.04
RXJ1709.5-263 51336.321 257.3760 -26.66 3.05 0.56 3.10
RXS_J172006.1 51336.275 260.0254 -31.28 32.76 2.66 4.78
RXS_J172525.5 51336.257 261.3563 -32.95 22.81 5.95 15.40
RXS_J173251.1 51336.246 263.2129 -34.79 24.97 4.48 51.70
RXS_J175428.3 51336.312 268.6179 -26.34 -8.52 3.84 33.67
RXS_J180326.2 51336.314 270.8417 -25.27 112.37 16.23 5706.68
RXS_J180824.5 51336.323 272.1021 -23.15 9.98 2.89 13.61
R_1832-330 51336.236 278.9317 -32.99 87.33 1.19 3.03
SAXJ1747.0-2853 51336.301 266.7879 -28.88 121.88 67.40 268.85
SAXJ1750.8-2900 51336.293 267.6000 -29.03 17.90 8.02 62.13
SAXJ1753.5-2349 51336.324 268.3917 -23.82 -1.53 3.49 16.98
SAXJ1802.7-2017 51336.335 270.6663 -20.29 484.60 110.50 4606.21
SAXJ1806.5-2215 51336.329 271.6417 -22.25 1.75 2.72 20.72
SAXJ1808.4-3658 51336.230 272.1208 -36.98 -2.04 0.98 3.07
SAXJ1808.4-365P 51336.236 271.1200 -35.50 -2.85 2.31 3.32
SAXJ1810.8-2609 51336.308 272.6850 -26.15 1.39 2.29 8.52
SGR_1806-20 51336.335 272.1642 -20.41 1.99 3.90 28.78
SGR_A 51336.301 266.4000 -29.00 246.44 88.45 276.69
SLX_1735-269 51336.312 264.5647 -27.00 198.26 6.29 16.02
SLX_1737-282 51336.304 265.2360 -28.31 15.14 11.31 40.86
SLX_1744-300 51336.276 266.8580 -30.04 319.97 16.02 154.93
SLX_1746-331 51336.251 267.4608 -33.20 -0.28 4.46 17.78
SW_J1729.9-3437 51336.248 262.5375 -34.61 -10.82 5.26 140.83
TERZAN_2 51336.282 261.8880 -30.80 293.76 5.92 13.93
WGAJ1715.3-2635 51336.320 258.8370 -26.60 -2.16 1.64 3.31
XTE_J1710-281 51336.310 257.5500 -28.12 52.76 1.06 3.26
XTE_J1710-281P 51336.306 258.5500 -28.91 -2.12 7.65 3.96
XTE_J1719-291 51336.303 259.8890 -29.06 -2.82 3.73 6.02
XTE_J1719-356 51336.243 259.9700 -35.68 2.08 1.15 16.61
XTE_J1720-318 51336.271 259.9961 -31.75 -8.19 5.55 25.79
XTE_J1723-376 51336.234 260.9000 -37.65 -0.12 0.72 15.92
XTE_J1726-283 51336.309 261.6570 -28.30 -5.82 6.29 8.13
XTE_J1728-295 51336.302 262.1570 -29.52 0.78 2.68 12.25
XTE_J1734-234 51336.332 263.5280 -23.36 -6.88 2.88 11.04
XTE_J1737-376 51336.232 264.4950 -37.77 -0.55 3.30 7.56
XTE_J1739-285 51336.304 264.9790 -28.48 26.97 11.11 35.16
XTE_J1739-302 51336.281 264.7500 -30.27 5.01 7.69 37.21
XTE_J1743-363 51336.237 265.7415 -36.33 9.30 3.19 8.04
XTE_J1744-230 51336.331 266.0350 -23.12 33.68 3.53 9.04
XTE_J1747-274 51336.308 266.9095 -27.44 -26.13 22.94 340.61
XTE_J1748-288 51336.302 267.0210 -28.47 -0.91 49.97 191.03
XTE_J1751-305 51336.262 267.8062 -30.62 23.42 16.20 31.65
XTE_J1752-223 51336.331 268.0440 -22.32 -4.00 3.64 12.42
XTE_J1752-280 51336.303 268.2000 -28.00 31.40 6.30 29.93
XTE_J1755-312 51336.259 268.7820 -31.16 4.22 4.13 22.26
XTE_J1756-342 51336.244 269.0228 -34.21 7.97 2.83 5.66
XTE_J1757-306 51336.261 269.4130 -30.66 35.12 4.61 12.22
XTE_J1759-220 51336.331 269.9404 -22.03 -5.26 4.40 18.48
XTE_J1805-295 51336.264 271.4045 -29.52 3.62 4.87 11.89
XTE_J1807-294 51336.264 271.7441 -29.40 6.61 4.79 9.22
XTE_J1812-230 51336.322 273.2000 -23.00 3.25 2.30 10.71
XTE_J1814-338 51336.240 273.4126 -33.77 2.79 2.58 3.14
XTE_J1817-330 51336.243 274.4250 -33.02 -3.23 1.88 3.10
XTE_J1818-245 51336.313 274.6050 -24.54 1.72 2.17 16.81
XTE_J1819-254 51336.308 274.8300 -25.41 139.39 3.56 4.92
XTE_J1819-254P 51336.305 273.8300 -26.41 7.44 4.22 5.60

Scan Light Curve

Light Curve - Day 1983f - Part 1

Legend
--------------------------
  8 - XTE J1719-356   
 18 - 4U 1728-34      
 20 - RXS J173251.1   
 35 - XTE J1743-363   
 55 - A1744-361       
 61 - 4U 1746-371     
 72 - XTE J1756-342   
 96 - XTE J1814-338   
103 - 4U 1820-30      
105 - R 1832-330      
Light Curve - Day 1983f - Part 2

Legend
--------------------------
  4 - 4U 1711-34      
 10 - RXS J172006.1   
 13 - RXS J172525.5   
 15 - TERZAN 2        
 18 - 4U 1728-34      
 22 - MXB 1730-33     
 28 - IGR J17375-3022 
 31 - XTE J1739-302   
 36 - 1E1740.7-2942   
 38 - KS 1741-293     
 39 - GCRT J1745-3009 
 40 - EXO 1742-326    
 42 - 2S1742-294      
 45 - H1743-322       
 48 - SLX 1744-300    
 60 - 2E1746.7-3225   
 62 - SAXJ1750.8-2900 
 63 - GRS 1747-312    
 65 - XTE J1751-305   
 71 - XTE J1755-312   
 74 - XTE J1757-306   
 83 - XTE J1805-295   
 84 - XTE J1807-294   
103 - 4U 1820-30      
195 - 4U 1820-30      
Light Curve - Day 1983f - Part 3

Legend
--------------------------
  0 - RXJ1709.5-263   
  1 - XTE J1710-281   
  6 - IGR J17191-2821 
 10 - RXS J172006.1   
 15 - TERZAN 2        
 25 - KS 1731-260     
 26 - KS 1732-273     
 27 - GRS 1734-292    
 28 - IGR J17375-3022 
 30 - SLX 1735-269    
 31 - XTE J1739-302   
 32 - XTE J1739-285   
 33 - SLX 1737-282    
 36 - 1E1740.7-2942   
 38 - KS 1741-293     
 39 - GCRT J1745-3009 
 41 - SGR A           
 42 - 2S1742-294      
 43 - GCRT J1746-2757 
 46 - SAXJ1747.0-2853 
 48 - SLX 1744-300    
 51 - GX 3+1          
 57 - AX J1749.1-2639 
 58 - IGR J17497-2821 
 62 - SAXJ1750.8-2900 
 68 - XTE J1752-280   
 77 - GX 5-1          
 78 - GRS 1758-258    
 81 - RXS J180326.2   
 93 - SAXJ1810.8-2609 
100 - XTE J1818-245   
101 - XTE J1819-254   
102 - XTE J1819-254P  
104 - GS 1826-238     
193 - GX 3+1          
194 - GX 5-1          
Light Curve - Day 1983f - Part 4

Legend
--------------------------
  0 - RXJ1709.5-263   
  3 - OPH CLU         
 19 - GX 1+4          
 21 - IGR J17331-2406 
 25 - KS 1731-260     
 37 - XTE J1744-230   
 79 - GX 9+1          
 80 - SAXJ1802.7-2017 
 85 - SAXJ1806.5-2215 
 87 - RXS J180824.5   
 90 - SGR 1806-20     
 95 - XTE J1812-230   
150 - G11.2-0.3       
191 - GX 1+4          
192 - GX 1+4          
194 - GX 5-1          

Top | Maps | Commentary | Sources | Scan Light Curves

Generated automatically on Fri Mar 18 22:56:30 2011 by Craig Markwardt