RXTE Galactic Center Observation
Observation Date: | 1999-03-11 |
Mission Day: | 1895d |
Modified Julian Day: | 51248.163 |
Mission times: | 163742065.00- 163751639.00 |
Scan type: | regular |
Main Page: | Observation List | Source List |
Observation Page: | Top | Commentary | Sources | Scan Light Curves |
Map Page: | Reconstructed Model | Residuals |
Scan Light Curves: | Parts 1 | 2 | 3 | 4 |
Craig Markwardt writes: I will stand in for Frank today, since he seems to be out. Today's (March 11) galactic bulge scans are North/South. * XTE J1710-281 is back to about 95 ct/s (10 mCrab), which is close to it's previous high of a month ago. This is the suspected eclipser/dipper. * XTE J1819-254 is stronger than the last time, up to about 45 ct/s (4 mCrab). * XTE J1723-376 is steady at about 660 ct/s (66 mCrab). * The weak source near (265.6,-23.1) has faded to less than 1 mCrab. * K1731-26, a bursting source, continues to fade. From its peak at 1600 ct/s about ten days ago it has declined to about 700 ct/s. * No new bright sources or other dramatic transient activity. Craig
Source | Time (MJD) | RA (2000) | DEC (2000) | Rate (ct/s/5PCU) | Error (ct/s/5PCU) | Bkg (ct/s/5PCU) |
---|---|---|---|---|---|---|
1E1740.7-2942 | 51248.194 | 265.9604 | -29.75 | 227.49 | 22.02 | 182.27 |
1E1743.1-2843 | 51248.198 | 266.5792 | -28.72 | 100.18 | 57.60 | 263.72 |
2E1746.7-3225 | 51248.196 | 267.5144 | -32.43 | 10.45 | 6.42 | 16.71 |
2S1742-294 | 51248.196 | 266.5230 | -29.52 | 129.50 | 26.25 | 371.20 |
2S1803-245 | 51248.253 | 271.7090 | -24.59 | 4.63 | 4.64 | 12.32 |
4U_1711-34 | 51248.165 | 258.5800 | -34.05 | 352.48 | 17.81 | 8.49 |
4U_1728-34 | 51248.179 | 262.9920 | -33.83 | 915.39 | 13.82 | 34.93 |
4U_1820-30 | 51248.257 | 275.9280 | -30.37 | 2250.05 | 47.93 | 2.21 |
4U_1820-30 | 51248.260 | 275.9280 | -30.37 | 2324.91 | 20.94 | 2.21 |
4U_1820-30 | 51248.264 | 275.9280 | -30.37 | 2207.86 | 41.45 | 2.21 |
A1744-361 | 51248.191 | 267.0800 | -36.12 | 4.94 | 1.71 | 15.08 |
AX_J1749.1-2639 | 51248.225 | 267.3000 | -26.65 | 8.17 | 26.14 | 1678.97 |
EXO_1722-363 | 51248.171 | 261.4810 | -36.41 | -3.71 | 5.71 | 22.00 |
EXO_1742-326 | 51248.193 | 266.3690 | -32.69 | 25.95 | 6.24 | 21.68 |
EXO_1745-248 | 51248.234 | 267.0208 | -24.78 | 1.23 | 2.42 | 15.58 |
GCRT_J1745-3009 | 51248.195 | 266.2708 | -30.16 | 21.76 | 11.82 | 300.63 |
GCRT_J1746-2757 | 51248.201 | 266.5417 | -27.95 | 59.16 | 10.79 | 59.19 |
GRS_1734-292 | 51248.189 | 264.3533 | -29.18 | 41.41 | 4.62 | 20.63 |
GRS_1747-312 | 51248.209 | 267.6900 | -31.29 | 27.95 | 9.95 | 3.07 |
GRS_1758-258 | 51248.246 | 270.3025 | -25.74 | 229.49 | 15.38 | 3940.47 |
GS_1826-238 | 51248.270 | 277.3623 | -23.79 | 338.69 | 0.96 | 2.55 |
GX_1+4 | 51248.184 | 263.0090 | -24.75 | 229.87 | 11.02 | 5.94 |
GX_1+4 | 51248.190 | 263.0090 | -24.75 | 163.39 | 11.41 | 5.94 |
GX_3+1 | 51248.199 | 266.9830 | -26.56 | 2417.97 | 32.51 | 31.10 |
GX_3+1 | 51248.233 | 266.9830 | -26.56 | 2336.84 | 47.98 | 31.10 |
GX_5-1 | 51248.242 | 270.2840 | -25.08 | 12870.31 | 139.17 | 70.12 |
GX_5-1 | 51248.247 | 270.2840 | -25.08 | 13387.00 | 51.19 | 70.12 |
GX_5-1 | 51248.249 | 270.2840 | -25.08 | 13939.62 | 90.74 | 70.12 |
H1743-322 | 51248.194 | 266.5700 | -32.24 | 13.17 | 4.61 | 29.56 |
IGR_J17191-2821 | 51248.171 | 259.7700 | -28.35 | 6.36 | 2.42 | 3.84 |
IGR_J17331-2406 | 51248.190 | 263.2833 | -24.11 | 5.22 | 2.68 | 47.25 |
IGR_J17375-3022 | 51248.187 | 264.3946 | -30.38 | 12.12 | 6.47 | 28.49 |
IGR_J17497-2821 | 51248.217 | 267.4041 | -28.36 | 28.84 | 15.19 | 77.42 |
IGR_J17511-3057 | 51248.210 | 267.7875 | -30.96 | -31.38 | 14.46 | 52.28 |
IGR_J17586-2129 | 51248.248 | 269.6440 | -21.39 | 4.63 | 2.68 | 36.51 |
K1724-356 | 51248.174 | 261.9133 | -35.73 | -3.41 | 2.72 | 24.47 |
KS_1731-260 | 51248.189 | 263.5539 | -26.09 | 775.59 | 11.12 | 8.10 |
KS_1732-273 | 51248.189 | 263.9958 | -27.44 | -0.15 | 5.62 | 44.00 |
KS_1741-293 | 51248.196 | 266.2042 | -29.35 | 66.12 | 51.18 | 383.06 |
MXB_1730-33 | 51248.180 | 263.3498 | -33.39 | 1.64 | 7.61 | 417.43 |
NGC_6440 | 51248.241 | 267.2195 | -20.36 | 7.04 | 17.59 | 5.60 |
OPH_CLU | 51248.170 | 258.1580 | -23.39 | 275.21 | 2.27 | 2.15 |
RXJ1709.5-263 | 51248.163 | 257.3760 | -26.66 | 0.74 | 0.57 | 2.21 |
RXS_J172006.1 | 51248.170 | 260.0254 | -31.28 | 12.79 | 4.32 | 11.44 |
RXS_J172525.5 | 51248.174 | 261.3563 | -32.95 | 17.15 | 2.63 | 14.51 |
RXS_J173251.1 | 51248.179 | 263.2129 | -34.79 | 18.58 | 4.22 | 48.62 |
RXS_J175428.3 | 51248.238 | 268.6179 | -26.34 | 11.25 | 5.98 | 32.72 |
RXS_J180326.2 | 51248.248 | 270.8417 | -25.27 | -26.05 | 17.92 | 5855.37 |
RXS_J180824.5 | 51248.255 | 272.1021 | -23.15 | 8.99 | 1.75 | 12.78 |
R_1832-330 | 51248.265 | 278.9317 | -32.99 | 65.70 | 3.96 | 2.14 |
SAXJ1747.0-2853 | 51248.202 | 266.7879 | -28.88 | 168.52 | 32.15 | 216.86 |
SAXJ1750.8-2900 | 51248.216 | 267.6000 | -29.03 | 24.04 | 6.14 | 67.87 |
SAXJ1753.5-2349 | 51248.240 | 268.3917 | -23.82 | -4.05 | 2.44 | 16.09 |
SAXJ1806.5-2215 | 51248.255 | 271.6417 | -22.25 | 2.44 | 0.64 | 19.80 |
SAXJ1808.4-365P | 51248.237 | 271.1200 | -35.50 | -5.33 | 2.01 | 2.44 |
SAXJ1810.8-2609 | 51248.254 | 272.6850 | -26.15 | 1.96 | 2.14 | 7.58 |
SGR_1806-20 | 51248.262 | 272.1642 | -20.41 | 18.61 | 5.68 | 25.93 |
SGR_A | 51248.196 | 266.4000 | -29.00 | 79.34 | 72.11 | 332.93 |
SLX_1735-269 | 51248.191 | 264.5647 | -27.00 | 111.81 | 5.32 | 14.06 |
SLX_1737-282 | 51248.192 | 265.2360 | -28.31 | 16.01 | 12.07 | 36.51 |
SLX_1744-300 | 51248.197 | 266.8580 | -30.04 | 281.77 | 13.76 | 112.29 |
SLX_1746-331 | 51248.196 | 267.4608 | -33.20 | 11.36 | 3.58 | 12.44 |
SW_J1729.9-3437 | 51248.176 | 262.5375 | -34.61 | -6.56 | 5.44 | 127.15 |
SW_J1756.9-2508 | 51248.241 | 269.2380 | -25.11 | -7.83 | 4.28 | 690.67 |
TERZAN_2 | 51248.178 | 261.8880 | -30.80 | 269.65 | 6.30 | 13.04 |
WGAJ1715.3-2635 | 51248.170 | 258.8370 | -26.60 | 4.27 | 2.07 | 2.42 |
XTE_J1710-281 | 51248.164 | 257.5500 | -28.12 | 97.25 | 4.93 | 2.37 |
XTE_J1710-281P | 51248.166 | 258.5500 | -28.91 | -0.67 | 3.98 | 3.11 |
XTE_J1719-291 | 51248.171 | 259.8890 | -29.06 | 0.30 | 2.47 | 6.03 |
XTE_J1719-356 | 51248.166 | 259.9700 | -35.68 | 2.90 | 2.30 | 15.72 |
XTE_J1720-318 | 51248.169 | 259.9961 | -31.75 | 7.02 | 4.21 | 14.99 |
XTE_J1723-376 | 51248.166 | 260.9000 | -37.65 | 685.46 | 6.54 | 15.04 |
XTE_J1726-283 | 51248.179 | 261.6570 | -28.30 | 3.17 | 2.35 | 7.24 |
XTE_J1728-295 | 51248.179 | 262.1570 | -29.52 | 9.13 | 3.03 | 11.36 |
XTE_J1734-234 | 51248.191 | 263.5280 | -23.36 | -0.09 | 0.81 | 4.62 |
XTE_J1739-285 | 51248.192 | 264.9790 | -28.48 | 22.23 | 11.91 | 34.60 |
XTE_J1739-302 | 51248.189 | 264.7500 | -30.27 | 3.85 | 6.65 | 38.81 |
XTE_J1743-363 | 51248.187 | 265.7415 | -36.33 | 48.15 | 1.06 | 7.14 |
XTE_J1744-230 | 51248.215 | 266.0350 | -23.12 | 46.48 | 6.00 | 8.15 |
XTE_J1747-274 | 51248.210 | 266.9095 | -27.44 | 13.36 | 12.26 | 265.46 |
XTE_J1748-288 | 51248.208 | 267.0210 | -28.47 | -27.38 | 34.70 | 228.22 |
XTE_J1751-305 | 51248.212 | 267.8062 | -30.62 | 26.26 | 9.85 | 10.25 |
XTE_J1752-223 | 51248.241 | 268.0440 | -22.32 | 0.55 | 1.83 | 11.53 |
XTE_J1752-280 | 51248.234 | 268.2000 | -28.00 | 19.13 | 4.49 | 27.55 |
XTE_J1755-312 | 51248.224 | 268.7820 | -31.16 | 7.46 | 3.61 | 13.88 |
XTE_J1756-342 | 51248.216 | 269.0228 | -34.21 | 5.33 | 1.96 | 4.77 |
XTE_J1757-306 | 51248.236 | 269.4130 | -30.66 | 14.99 | 3.07 | 12.00 |
XTE_J1759-220 | 51248.248 | 269.9404 | -22.03 | 1.02 | 1.83 | 20.04 |
XTE_J1805-295 | 51248.244 | 271.4045 | -29.52 | 3.29 | 5.12 | 11.42 |
XTE_J1807-294 | 51248.246 | 271.7441 | -29.40 | 7.23 | 5.02 | 8.11 |
XTE_J1810-189 | 51248.262 | 272.5863 | -19.07 | 31.35 | 28.55 | 35.72 |
XTE_J1810-197 | 51248.262 | 272.4630 | -19.73 | -9.35 | 6.08 | 48.26 |
XTE_J1812-230 | 51248.261 | 273.2000 | -23.00 | 6.17 | 2.51 | 9.80 |
XTE_J1814-338 | 51248.246 | 273.4126 | -33.77 | 5.40 | 2.91 | 2.25 |
XTE_J1817-330 | 51248.251 | 274.4250 | -33.02 | -1.42 | 1.58 | 2.22 |
XTE_J1818-245 | 51248.262 | 274.6050 | -24.54 | 6.43 | 3.03 | 8.37 |
XTE_J1819-254 | 51248.262 | 274.8300 | -25.41 | 44.66 | 3.42 | 4.41 |
XTE_J1819-254P | 51248.257 | 273.8300 | -26.41 | 1.06 | 3.01 | 4.72 |
Legend -------------------------- 1 - XTE J1710-281 3 - OPH CLU 4 - 4U 1711-34 5 - WGAJ1715.3-2635 6 - IGR J17191-2821 8 - XTE J1719-356 9 - XTE J1720-318 10 - RXS J172006.1 11 - XTE J1723-376 13 - RXS J172525.5 14 - XTE J1726-283 15 - TERZAN 2 16 - XTE J1728-295 18 - 4U 1728-34 19 - GX 1+4 20 - RXS J173251.1 22 - MXB 1730-33 | |
Legend -------------------------- 19 - GX 1+4 21 - IGR J17331-2406 25 - KS 1731-260 27 - GRS 1734-292 28 - IGR J17375-3022 30 - SLX 1735-269 31 - XTE J1739-302 32 - XTE J1739-285 33 - SLX 1737-282 35 - XTE J1743-363 36 - 1E1740.7-2942 37 - XTE J1744-230 38 - KS 1741-293 39 - GCRT J1745-3009 40 - EXO 1742-326 41 - SGR A 42 - 2S1742-294 43 - GCRT J1746-2757 44 - 1E1743.1-2843 45 - H1743-322 46 - SAXJ1747.0-2853 48 - SLX 1744-300 50 - XTE J1747-274 51 - GX 3+1 55 - A1744-361 57 - AX J1749.1-2639 58 - IGR J17497-2821 59 - SLX 1746-331 60 - 2E1746.7-3225 62 - SAXJ1750.8-2900 63 - GRS 1747-312 65 - XTE J1751-305 71 - XTE J1755-312 72 - XTE J1756-342 191 - GX 1+4 | |
Legend -------------------------- 37 - XTE J1744-230 46 - SAXJ1747.0-2853 50 - XTE J1747-274 53 - EXO 1745-248 57 - AX J1749.1-2639 58 - IGR J17497-2821 62 - SAXJ1750.8-2900 63 - GRS 1747-312 65 - XTE J1751-305 68 - XTE J1752-280 70 - RXS J175428.3 71 - XTE J1755-312 72 - XTE J1756-342 74 - XTE J1757-306 75 - IGR J17586-2129 77 - GX 5-1 78 - GRS 1758-258 83 - XTE J1805-295 84 - XTE J1807-294 96 - XTE J1814-338 192 - GX 3+1 193 - GX 5-1 194 - GX 5-1 | |
Legend -------------------------- 85 - SAXJ1806.5-2215 86 - 2S1803-245 87 - RXS J180824.5 90 - SGR 1806-20 92 - XTE J1810-189 93 - SAXJ1810.8-2609 95 - XTE J1812-230 100 - XTE J1818-245 101 - XTE J1819-254 103 - 4U 1820-30 104 - GS 1826-238 105 - R 1832-330 150 - G11.2-0.3 195 - 4U 1820-30 196 - 4U 1820-30 |
Top | Maps | Commentary | Sources | Scan Light Curves
Generated automatically on Fri Mar 18 22:51:29 2011 by Craig Markwardt