RXTE Galactic Center Observation
Observation Date: | 1999-07-18 |
Mission Day: | 2024j |
Modified Julian Day: | 51377.395 |
Mission times: | 174907761.00- 174917039.00 |
Scan type: | cross |
Main Page: | Observation List | Source List |
Observation Page: | Top | Commentary | Sources | Scan Light Curves |
Map Page: | Reconstructed Model | Residuals |
Scan Light Curves: | Parts 1 | 2 | 3 | 4 |
Craig Markwardt writes: Here is a report for the galactic scans of July 15 and 18 (mission days 2021 and 2024). I had been away for two weeks and processing wasn't fixed until now. * GRS 1747-312 (Terzan 6) is on a slow increase, up to about 30 ct/s/PCU (2-10 keV). For comparison, its previous quiescent level was near 10 ct/s, the recent outburst went to 350 ct/s. * KS 1731-260 seems to have entered another high cycle, jumping from 650 ct/s to 1250 ct/s in three days time. This is about the third time we have seen this. For David Smith, there doesn't seem to be any unusual activity of 1E1740.7-2942 or GRS 1758-258. Nothing looks out of the ordinary in the neighborhood, but of course there are bright sources in both areas that confuse the source fitting algorithm some. In the past week a new set of observations have finished. Because of observing constraints of another proposals we had to chop the observation into small chunks. I anticipate there may be problems, so the analysis may be delayed. Craig
Source | Time (MJD) | RA (2000) | DEC (2000) | Rate (ct/s/5PCU) | Error (ct/s/5PCU) | Bkg (ct/s/5PCU) |
---|---|---|---|---|---|---|
1E1740.7-2942 | 51377.453 | 265.9604 | -29.75 | 240.85 | 34.43 | 236.86 |
1E1743.1-2843 | 51377.468 | 266.5792 | -28.72 | -8.68 | 79.62 | 319.54 |
2E1746.7-3225 | 51377.421 | 267.5144 | -32.43 | 5.42 | 5.57 | 18.58 |
2S1742-294 | 51377.455 | 266.5230 | -29.52 | 153.16 | 50.28 | 405.70 |
2S1803-245 | 51377.482 | 271.7090 | -24.59 | 6.68 | 5.62 | 14.85 |
4U_1711-34 | 51377.419 | 258.5800 | -34.05 | 15.10 | 1.02 | 9.73 |
4U_1728-34 | 51377.418 | 262.9920 | -33.83 | 992.42 | 20.87 | 38.80 |
4U_1746-371 | 51377.398 | 267.5523 | -37.05 | 527.17 | 13.83 | 4.89 |
4U_1820-30 | 51377.416 | 275.9280 | -30.37 | 2611.60 | 51.62 | 3.45 |
4U_1820-30 | 51377.423 | 275.9280 | -30.37 | 2679.84 | 30.90 | 3.45 |
A1744-361 | 51377.403 | 267.0800 | -36.12 | 1.05 | 4.88 | 17.86 |
AX_J1749.1-2639 | 51377.476 | 267.3000 | -26.65 | 64.94 | 29.16 | 1623.23 |
EXO_1722-363 | 51377.405 | 261.4810 | -36.41 | 12.50 | 3.37 | 20.52 |
EXO_1742-326 | 51377.420 | 266.3690 | -32.69 | 41.01 | 7.02 | 21.94 |
EXO_1745-248 | 51377.487 | 267.0208 | -24.78 | -1.68 | 3.30 | 16.83 |
GCRT_J1745-3009 | 51377.442 | 266.2708 | -30.16 | 52.74 | 21.25 | 285.66 |
GCRT_J1746-2757 | 51377.471 | 266.5417 | -27.95 | 70.67 | 19.92 | 36.50 |
GRS_1734-292 | 51377.468 | 264.3533 | -29.18 | 46.78 | 6.28 | 21.54 |
GRS_1747-312 | 51377.425 | 267.6900 | -31.29 | 74.18 | 16.19 | -21.79 |
GRS_1758-258 | 51377.478 | 270.3025 | -25.74 | 131.88 | 14.01 | 4289.79 |
GS_1826-238 | 51377.480 | 277.3623 | -23.79 | 323.07 | 2.33 | 3.79 |
GX_1+4 | 51377.489 | 263.0090 | -24.75 | 302.65 | 10.97 | 5.81 |
GX_1+4 | 51377.493 | 263.0090 | -24.75 | 327.41 | 10.80 | 5.81 |
GX_3+1 | 51377.475 | 266.9830 | -26.56 | 2248.53 | 47.75 | 71.98 |
GX_3+1 | 51377.480 | 266.9830 | -26.56 | 2256.61 | 34.33 | 71.98 |
GX_5-1 | 51377.479 | 270.2840 | -25.08 | 15343.29 | 122.47 | 89.14 |
GX_5-1 | 51377.483 | 270.2840 | -25.08 | 15071.67 | 65.64 | 89.14 |
GX_9+1 | 51377.501 | 270.3846 | -20.53 | 6137.31 | 103.74 | 291.34 |
H1743-322 | 51377.421 | 266.5700 | -32.24 | 11.30 | 8.04 | 37.31 |
IGR_J17191-2821 | 51377.476 | 259.7700 | -28.35 | 0.14 | 4.57 | 4.68 |
IGR_J17375-3022 | 51377.445 | 264.3946 | -30.38 | 7.14 | 8.69 | 33.35 |
IGR_J17497-2821 | 51377.468 | 267.4041 | -28.36 | 32.67 | 26.72 | 58.96 |
IGR_J17511-3057 | 51377.427 | 267.7875 | -30.96 | -87.02 | 30.27 | 107.66 |
IGR_J17586-2129 | 51377.499 | 269.6440 | -21.39 | -2.63 | 5.12 | 34.22 |
K1724-356 | 51377.409 | 261.9133 | -35.73 | -18.13 | 8.88 | 28.72 |
KS_1731-260 | 51377.483 | 263.5539 | -26.09 | 1268.23 | 16.10 | 9.34 |
KS_1732-273 | 51377.476 | 263.9958 | -27.44 | -10.26 | 4.95 | 43.54 |
KS_1741-293 | 51377.457 | 266.2042 | -29.35 | 139.18 | 89.27 | 400.33 |
MXB_1730-33 | 51377.420 | 263.3498 | -33.39 | 5.64 | 10.28 | 450.83 |
OPH_CLU | 51377.499 | 258.1580 | -23.39 | 647.39 | 23.82 | 3.40 |
RXJ1709.5-263 | 51377.487 | 257.3760 | -26.66 | 2.65 | 0.68 | 3.45 |
RXS_J172006.1 | 51377.445 | 260.0254 | -31.28 | 20.68 | 3.51 | -0.93 |
RXS_J172525.5 | 51377.423 | 261.3563 | -32.95 | 20.62 | 6.87 | 15.76 |
RXS_J173251.1 | 51377.412 | 263.2129 | -34.79 | 20.39 | 5.51 | 55.90 |
RXS_J175428.3 | 51377.476 | 268.6179 | -26.34 | 16.16 | 4.82 | 33.99 |
RXS_J180326.2 | 51377.479 | 270.8417 | -25.27 | 83.34 | 17.54 | 6300.33 |
RXS_J180824.5 | 51377.489 | 272.1021 | -23.15 | 10.46 | 3.56 | 14.03 |
R_1832-330 | 51377.402 | 278.9317 | -32.99 | 68.21 | 1.37 | 3.39 |
SAXJ1747.0-2853 | 51377.467 | 266.7879 | -28.88 | 201.54 | 78.28 | 165.16 |
SAXJ1750.8-2900 | 51377.457 | 267.6000 | -29.03 | 26.68 | 9.59 | 68.70 |
SAXJ1753.5-2349 | 51377.490 | 268.3917 | -23.82 | 2.46 | 4.34 | 17.34 |
SAXJ1802.7-2017 | 51377.501 | 270.6663 | -20.29 | 443.74 | 169.77 | 3861.34 |
SAXJ1805.5-2031 | 51377.501 | 271.3917 | -20.51 | -12.57 | 12.57 | 432.95 |
SAXJ1806.5-2215 | 51377.495 | 271.6417 | -22.25 | 3.58 | 3.31 | 21.09 |
SAXJ1808.4-3658 | 51377.396 | 272.1208 | -36.98 | -1.66 | 0.76 | 3.43 |
SAXJ1808.4-365P | 51377.402 | 271.1200 | -35.50 | -0.80 | 3.08 | 3.68 |
SAXJ1810.8-2609 | 51377.474 | 272.6850 | -26.15 | 8.54 | 3.25 | 8.95 |
SGR_1806-20 | 51377.501 | 272.1642 | -20.41 | 11.87 | 6.42 | 26.45 |
SGR_A | 51377.467 | 266.4000 | -29.00 | 101.97 | 96.12 | 331.99 |
SLX_1735-269 | 51377.477 | 264.5647 | -27.00 | 105.64 | 6.06 | 12.57 |
SLX_1737-282 | 51377.470 | 265.2360 | -28.31 | 24.99 | 12.86 | 34.75 |
SLX_1744-300 | 51377.443 | 266.8580 | -30.04 | 192.33 | 17.35 | 143.38 |
SLX_1746-331 | 51377.417 | 267.4608 | -33.20 | 13.85 | 5.52 | 12.94 |
SW_J1729.9-3437 | 51377.414 | 262.5375 | -34.61 | 2.56 | 6.59 | 136.62 |
SW_J1756.9-2508 | 51377.482 | 269.2380 | -25.11 | -8.93 | 9.82 | 745.07 |
TERZAN_2 | 51377.448 | 261.8880 | -30.80 | 290.86 | 7.26 | 14.29 |
WGAJ1715.3-2635 | 51377.486 | 258.8370 | -26.60 | 3.08 | 2.17 | 3.66 |
XTE_J1710-281 | 51377.476 | 257.5500 | -28.12 | 21.02 | 1.00 | 3.61 |
XTE_J1710-281P | 51377.471 | 258.5500 | -28.91 | -10.17 | 11.71 | 4.28 |
XTE_J1719-291 | 51377.469 | 259.8890 | -29.06 | -1.45 | 4.98 | 5.85 |
XTE_J1719-356 | 51377.409 | 259.9700 | -35.68 | 2.72 | 1.39 | 16.97 |
XTE_J1720-318 | 51377.438 | 259.9961 | -31.75 | -20.40 | 7.48 | 20.15 |
XTE_J1723-376 | 51377.400 | 260.9000 | -37.65 | 1.94 | 0.90 | 16.28 |
XTE_J1726-283 | 51377.474 | 261.6570 | -28.30 | 5.89 | 8.81 | 8.48 |
XTE_J1728-295 | 51377.468 | 262.1570 | -29.52 | 6.49 | 3.76 | 12.60 |
XTE_J1734-234 | 51377.498 | 263.5280 | -23.36 | -2.29 | 2.77 | 5.03 |
XTE_J1737-376 | 51377.398 | 264.4950 | -37.77 | -3.76 | 3.84 | 7.91 |
XTE_J1739-285 | 51377.469 | 264.9790 | -28.48 | 18.07 | 13.24 | 42.75 |
XTE_J1739-302 | 51377.446 | 264.7500 | -30.27 | 9.27 | 9.90 | 36.75 |
XTE_J1743-363 | 51377.403 | 265.7415 | -36.33 | 14.31 | 4.04 | 8.36 |
XTE_J1744-230 | 51377.497 | 266.0350 | -23.12 | 32.23 | 4.25 | 9.39 |
XTE_J1747-274 | 51377.474 | 266.9095 | -27.44 | 9.18 | 17.89 | 268.83 |
XTE_J1748-288 | 51377.468 | 267.0210 | -28.47 | -46.73 | 53.77 | 201.95 |
XTE_J1751-305 | 51377.428 | 267.8062 | -30.62 | 63.00 | 19.04 | -14.32 |
XTE_J1752-223 | 51377.497 | 268.0440 | -22.32 | -8.60 | 4.22 | 12.78 |
XTE_J1752-280 | 51377.469 | 268.2000 | -28.00 | 16.73 | 8.27 | 29.38 |
XTE_J1755-312 | 51377.424 | 268.7820 | -31.16 | 10.39 | 4.86 | 13.39 |
XTE_J1756-342 | 51377.410 | 269.0228 | -34.21 | 8.54 | 3.57 | 6.02 |
XTE_J1757-306 | 51377.427 | 269.4130 | -30.66 | 14.91 | 5.12 | 13.85 |
XTE_J1759-220 | 51377.497 | 269.9404 | -22.03 | -7.91 | 5.15 | 19.48 |
XTE_J1805-295 | 51377.430 | 271.4045 | -29.52 | 2.95 | 6.08 | 11.94 |
XTE_J1807-294 | 51377.430 | 271.7441 | -29.40 | 6.16 | 5.98 | 9.12 |
XTE_J1812-230 | 51377.488 | 273.2000 | -23.00 | 4.48 | 2.85 | 11.07 |
XTE_J1814-338 | 51377.406 | 273.4126 | -33.77 | 4.70 | 3.46 | 3.50 |
XTE_J1817-330 | 51377.409 | 274.4250 | -33.02 | 2.05 | 2.65 | 3.46 |
XTE_J1818-245 | 51377.475 | 274.6050 | -24.54 | -2.21 | 2.78 | 21.77 |
XTE_J1819-254 | 51377.473 | 274.8300 | -25.41 | 197.15 | 2.07 | 4.96 |
XTE_J1819-254P | 51377.471 | 273.8300 | -26.41 | 16.20 | 8.26 | 6.02 |
Legend -------------------------- 8 - XTE J1719-356 11 - XTE J1723-376 12 - EXO 1722-363 17 - SW J1729.9-3437 18 - 4U 1728-34 20 - RXS J173251.1 35 - XTE J1743-363 59 - SLX 1746-331 61 - 4U 1746-371 72 - XTE J1756-342 96 - XTE J1814-338 98 - XTE J1817-330 103 - 4U 1820-30 105 - R 1832-330 | |
Legend -------------------------- 4 - 4U 1711-34 10 - RXS J172006.1 13 - RXS J172525.5 15 - TERZAN 2 18 - 4U 1728-34 22 - MXB 1730-33 28 - IGR J17375-3022 31 - XTE J1739-302 36 - 1E1740.7-2942 38 - KS 1741-293 39 - GCRT J1745-3009 40 - EXO 1742-326 42 - 2S1742-294 45 - H1743-322 48 - SLX 1744-300 59 - SLX 1746-331 60 - 2E1746.7-3225 62 - SAXJ1750.8-2900 63 - GRS 1747-312 65 - XTE J1751-305 71 - XTE J1755-312 74 - XTE J1757-306 83 - XTE J1805-295 84 - XTE J1807-294 103 - 4U 1820-30 194 - 4U 1820-30 | |
Legend -------------------------- 0 - RXJ1709.5-263 1 - XTE J1710-281 5 - WGAJ1715.3-2635 10 - RXS J172006.1 14 - XTE J1726-283 15 - TERZAN 2 16 - XTE J1728-295 25 - KS 1731-260 27 - GRS 1734-292 28 - IGR J17375-3022 30 - SLX 1735-269 31 - XTE J1739-302 32 - XTE J1739-285 33 - SLX 1737-282 36 - 1E1740.7-2942 38 - KS 1741-293 39 - GCRT J1745-3009 41 - SGR A 42 - 2S1742-294 43 - GCRT J1746-2757 46 - SAXJ1747.0-2853 48 - SLX 1744-300 50 - XTE J1747-274 51 - GX 3+1 57 - AX J1749.1-2639 58 - IGR J17497-2821 62 - SAXJ1750.8-2900 68 - XTE J1752-280 70 - RXS J175428.3 77 - GX 5-1 78 - GRS 1758-258 81 - RXS J180326.2 86 - 2S1803-245 93 - SAXJ1810.8-2609 101 - XTE J1819-254 102 - XTE J1819-254P 104 - GS 1826-238 192 - GX 3+1 193 - GX 5-1 | |
Legend -------------------------- 0 - RXJ1709.5-263 3 - OPH CLU 5 - WGAJ1715.3-2635 19 - GX 1+4 25 - KS 1731-260 37 - XTE J1744-230 69 - SAXJ1753.5-2349 79 - GX 9+1 80 - SAXJ1802.7-2017 85 - SAXJ1806.5-2215 87 - RXS J180824.5 90 - SGR 1806-20 95 - XTE J1812-230 191 - GX 1+4 193 - GX 5-1 |
Top | Maps | Commentary | Sources | Scan Light Curves
Generated automatically on Fri Mar 18 22:58:04 2011 by Craig Markwardt